Evidence map›Paper›PMID 40373029›Full record

ArticlePloS one2025

Application of stochastic fractal search algorithm in novel harmonic blocking filter design for optimizing harmonic mitigation and hosting capacity in electric distribution systems.

Abdallah Aldosary, Ziad M Ali, Shady H E Abdel Aleem, Ahmed M Zobaa

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Abdallah AldosaryDepartment of Computer Engineering, College of Engineering, Prince Sattam bin Abdulaziz University, Ar Riyadh, Saudi Arabia.ORCID https://orcid.org/0000-0002-2967-3570
Ziad M AliDepartment of Electrical Engineering, College of Engineering in Wadi Alddawasir, Prince Sattam Bin Abdulaziz University, Wadi Alddawasir, Saudi Arabia.
Shady H E Abdel AleemDepartment of Electrical Engineering, Institute of Aviation Engineering and Technology, Giza, Egypt.ORCID https://orcid.org/0000-0003-2546-6352
Ahmed M ZobaaDepartment of Electrical Power Engineering, Faculty of Engineering, Cairo University, Giza, Egypt.ORCID https://orcid.org/0000-0002-9162-3005

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Power networks are being transformed by the incorporation of renewable energy sources (RES), such as photovoltaic systems and wind turbines, which also promote sustainability and lower carbon emissions. However, the widespread use of inverter-based RES threatens power quality and grid stability, with harmonic distortion being a key issue. System performance is compromised by harmonic distortion, elevating the risk of resonance and overheating equipment and increasing power losses. In this study, the Stochastic Fractal Search (SFS) algorithm is used to develop Harmonic Blocking Filters (HBF), an optimized passive power filter for reducing harmonic distortion and minimizing the system active power losses (PLOSS) in electric distribution systems. Two multi-objective optimization algorithms: Multi-Objective Artificial Hummingbird (MOAHA) and Multi-Objective Atomic Orbital Search (MOAOS) efficiently determine the ideal HBF design to maximize the system's Harmonic-Constrained Hosting Capacity (HCHC) and minimize PLOSS to support RES while minimizing voltage and current total demand distortion (THDV and TDDI). Three test systems (TS) are used to validate the HBF's superiority in mitigating the harmonics, minimizing PLOSS, and maximizing HCHC. In TS1, the SFS-optimized HBF decreases THDV by 78% and TDDI by 90% while maintaining PLOSS almost the same as compared to the previously obtained results in the literature. In TS2, the SFS-optimized HBF decreases THDV by 16.2%, TDDI by 99.96%, and PLOSS by 27.6% compared to the uncompensated case with no filter connected. In TS3, the SFS-optimized HBF decreases THDV by 45.71%, TDDI by 99.96%, and PLOSS by 33.26% compared to the uncompensated case. For the HCHC enhancement application, MOAOS has proven superior to MOAHA and the MOAOS-optimized HBF increases the system's HCHC by 4.18% and in TS3, this value is increased by 16.4% compared to the literature.

Indexed as

AlgorithmsElectric Power SuppliesFractalsRenewable EnergyElectricityStochastic Processes

Identifiers

PMID40373029
PMCPMC12080870

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.