Evidence map›Paper›PMID 40372939›Full record

ReviewACS sensors2025

Paper-Based Vertical Flow Assays for in Vitro Diagnostics and Environmental Monitoring.

Jaehyung Jeon, Heeseon Choi, Gyeo-Re Han, Rajesh Ghosh, Barath Palanisamy, Dino Di Carlo, Aydogan Ozcan, Sungsu Park

Abstract readReview
In one paragraph

Review in ACS sensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jaehyung JeonSchool of Mechanical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea.
Heeseon ChoiSchool of Mechanical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea.
Gyeo-Re HanDepartment of Electrical & Computer Engineering, University of California, Los Angeles, California 90095, United States.ORCID 0000-0003-3584-4433
Rajesh GhoshDepartment of Bioengineering, University of California, Los Angeles, California 90095, United States.ORCID 0000-0002-7408-8944
Barath PalanisamyDepartment of Bioengineering, University of California, Los Angeles, California 90095, United States.ORCID 0000-0002-7117-2876
Dino Di CarloDepartment of Bioengineering, University of California, Los Angeles, California 90095, United States.ORCID 0000-0003-3942-4284
Aydogan OzcanDepartment of Electrical & Computer Engineering, University of California, Los Angeles, California 90095, United States.ORCID 0000-0002-0717-683X
Sungsu ParkSchool of Mechanical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea.ORCID 0000-0003-3062-1302

Funding

A peptide-based point-of-care vertical flow assay for the rapid diagnosis of Lyme diseaseR44AI150060 · NIAID · BIOPEPTIDES, INC. · PI ARNABOLDI, PAUL MICHAEL, DI CARLO, DINO · 2020 to 2023
$3.3M
A point of care vertical flow assay for the direct detection of Babesia microti and the serodiagnosis of Lyme disease.R44AI184034 · NIAID · BIOPEPTIDES, INC. · PI ARNABOLDI, PAUL MICHAEL, DATTWYLER, RAYMOND JAMES · 2024 to 2025
$1.9M
NIAID NIH HHS R44 AI150060NIAID NIH HHS R44 AI184034
6 · The paper itself

Abstract

Microfluidic paper-based analytical devices (μPADs) are powerful tools for diagnostic and environmental monitoring. Being affordable and portable, μPADs enable rapid detection of small molecules, heavy metals, and biomolecules, thereby decentralizing diagnostics and expanding biosensor accessibility. However, the reliance on two-dimensional fluid flow restricts the utility of conventional μPADs, presenting challenges for applications that require simultaneous multibiomarker analysis from a single sample. Vertical flow paper-based analytical devices (VF-μPADs) overcome this challenge by allowing axial fluid movement through paper stacks, offering several advantages, including (1) enhanced multiplexing capabilities, (2) reduced hook effect for improved accuracy, and (3) shorter assay times. This review provides an overview of VF-μPADs technologies, exploring structural and functional performance trade-offs between VF-μPADs and conventional lateral flow systems. The sensing performance, fabrication methods, and applications in in vitro diagnostics and environmental monitoring are discussed. Furthermore, critical challenges─such as fabrication complexity, data analysis, and scalability─are addressed, along with proposed strategies for mitigating these barriers to facilitate broader adoption. By examining these strengths and challenges, this review presents the potential of VF-μPADs to advance point-of-care testing, particularly in resource-limited settings.

Indexed as

Biosensing TechniquesEnvironmental MonitoringLab-On-A-Chip DevicesMicrofluidic Analytical TechniquesPaperHumansEnvironmental monitoringIn vitro diagnosticsMultiplexingPaper-based analytical devicesPoint of care testingVertical flow assayVertical flow paper-based analytical devices

Identifiers

PMID40372939
PMCPMC12117607

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.