ArticleLaryngoscope investigative otolaryngology2025
Minimally Invasive Intraoperative Laser Vibrometry (MIVIB)-A Peroperative Method to Measure Fixation of the Ossicular Chain.
Article in Laryngoscope investigative otolaryngology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Conductive hearing loss requires the surgeon to evaluate ossicular movement to plan and execute surgery. An objective assessment of the ossicular chain with laser vibrometry would likely improve the results of ossiculoplasty. Methods: Minimally invasive intraoperative laser vibrometry (MIVIB), a fast and accurate technique, using a continuous time-domain signal that stimulates the Med-El FMT transducer attached to the malleus in a temporal bone model, was used to evaluate artificial fixation of the ossicular chain. Results: Through this analysis method, differing incus velocity responses were seen between simulated single and multiple ossicle fixations in frequencies above 1000 Hz (</> -25 dB respectively). The incus-umbo velocity ratio was shown to detect stapes fixation in both multiple and single ossicle fixations (> -20 and > -10 dB, respectively) highlighting the importance of determining between single and multiple ossicle fixations first. Conclusion: MIVIB provides an objective assessment of the ossicular chain to identify specific fixations and therefore assist the surgeon in improving surgical outcomes.
Identifiers
What OpenQuestion holds
Registered trials