Evidence map›Paper›PMID 40369539›Full record

ArticleBMC oral health2025

Effect of thickness on irradiance loss and temperature rise in indirect restorative materials: an in vitro study.

Aybike Bas, Nilay Ozturk Sheikholaemeh, Fatih Sengul, Fatma Sarac, Sera Simsek Derelioglu, Peris Celikel

Abstract read
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Aybike BasFaculty of Dentistry, Department of Pediatric Dentistry, Ataturk University, Erzurum, 25240, Turkey.ORCID http://orcid.org/0000-0002-5287-1727
Nilay Ozturk SheikholaemehFaculty of Dentistry, Department of Pediatric Dentistry, Ataturk University, Erzurum, 25240, Turkey.ORCID http://orcid.org/0000-0003-0311-6597
Fatih SengulFaculty of Dentistry, Department of Pediatric Dentistry, Ataturk University, Erzurum, 25240, Turkey.ORCID http://orcid.org/0000-0001-6087-148X
Fatma SaracFaculty of Dentistry, Department of Pediatric Dentistry, Ataturk University, Erzurum, 25240, Turkey.ORCID http://orcid.org/0000-0001-7508-6046
Sera Simsek DereliogluFaculty of Dentistry, Department of Pediatric Dentistry, Ataturk University, Erzurum, 25240, Turkey.ORCID http://orcid.org/0000-0001-5192-923X
Peris CelikelFaculty of Dentistry, Department of Pediatric Dentistry, Ataturk University, Erzurum, 25240, Turkey. celikelperis@gmail.com.ORCID http://orcid.org/0000-0002-1807-4281

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe polymerization extent of resin cement used for bonding indirect restorations is contingent upon the light transmittance of the indirect restoration materials and the light intensity of the employed light device. The temperature increase during the polymerization of these resin cements via light is a critical factor in preserving pulp health. The present study aimed to assess the optical properties of different thicknesses of indirect restorative materials such as feldspathic ceramics [Vitablocs Mark II, (VBM)], indirect composites [Gradia, (GRA)] and 3D printing resins [VarseoSmile Crown Plus, (VSC)] and the temperature rise on the undersurface of the materials during LED light application.

methodsThe irradiance loss, absorbance, and absorbance coefficient values of three indirect restorative materials (VBM, GRA, and VSC) with four different thicknesses (0.5, 1.0, 1.5, and 2.0 mm) were analyzed. A Valo Cordless (Ultradent, USA) LED light device was used as the light source. Light transmittance was measured using a radiometer, and the averages were recorded. The temperature variation (Δt) was recorded using a K-type thermocouple during light application. Data were statistically analyzed at a significance level of 0.05.

resultsIt was revealed that irradiance loss and absorption values increased, and absorption coefficient values decreased with the increase in thickness in the material groups. The irradiance loss values for VBM and GRA were comparable across all thicknesses. The irradiance loss value for the VSC group was comparable to that of the GRA group and distinct from the VBM group across all thicknesses, except at 0.5 mm (p < 0.05). The assessment of thickness and material groups regarding temperature increase revealed that temperature differential values diminished with more thickness, although no significant difference was seen between the groups (p > 0.05).

conclusionThe absorbance and irradiance loss values of indirect restorative materials escalated with greater thickness, particularly in the VSC group. The efficacy of light-polymerized resin cements may be negatively impacted; therefore, it is advisable to prolong the curing duration for thicker materials. Moreover, as the thickness grows, the thermal exposure of the materials diminishes, resulting in a reduced danger to pulp health.

Indexed as

Composite ResinsDental MaterialsResin CementsCeramicsCuring Lights, DentalIn Vitro TechniquesLightLight-Curing of Dental AdhesivesMaterials TestingPolymerizationTemperatureComposite ResinsDental MaterialsResin CementsComposite resinCuring lightPolymerisationTemperatureVita Mark II

Identifiers

PMID40369539
PMCPMC12079930

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.