Evidence map›Paper›PMID 40369532›Full record

ArticleBMC oral health2025

A comparative study of deformation in hexagonal and star-shaped implant screwdriver heads.

Amin Nourizadeh, Shima Ghasemi, Elnaz Shafiee, Sevda JafarZadeh, Fatemeh Bakhtiari

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Bioinformation · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Amin NourizadehDepartment of Prosthodontics, Faculty of Dentistry, Tabriz University of Medical Science, Tabriz, Iran.ORCID http://orcid.org/0000-0001-6229-9632
Shima GhasemiDepartment of Prosthodontics, Faculty of Dentistry, Tabriz University of Medical Science, Tabriz, Iran.ORCID http://orcid.org/0000-0003-1557-5096
Elnaz ShafieeDepartment of prosthodontics, Faculty of dentistry, Tabriz Medical Sciences, Islamic Azad University, Tehran, Iran.ORCID http://orcid.org/0000-0002-1825-5322
Sevda JafarZadehStudent Research Committee, Faculty of Dentistry, Tabriz University of Medical Science, Tabriz, Iran.
Fatemeh BakhtiariDepartment of Prosthodontics, Faculty of Dentistry, Shahed University, Tehran, Iran. fatemehbakh@yahoo.com.ORCID http://orcid.org/0000-0003-0860-7109

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDental implants are a popular and effective solution for replacing missing teeth. However, there are challenges such as screw loosening and component failure. This deformation can impact torque application and screw retention. While research has focused on implant system longevity, there is limited investigation into how different screwdriver head designs, particularly hexagonal and star-shaped, perform under repeated opening and closing cycles, which are crucial for long-term implant stability. The study compared the deformation characteristics of hexagonal and star-shaped implant screwdriver heads after multiple opening and closing cycles.

methodsIn this in vitro experimental study, abutments were placed on two implant systems mounted in die stone and torqued to 25 N/cm according to the manufacturer's recommendations, using 12 screwdrivers (n = six for each implant). The screwdriver heads underwent examination under a stereomicroscope at 50x magnification. Subsequently, the outline and deformation of the screwdriver head after 0, 50, 100, 200, and 300 opening and closing cycles were analyzed using AutoCAD software. The changes in the surface area of hexagonal and star-shaped driver heads after different cycles were statistically evaluated using SPSS 24 (α = 0.05).

resultsThe investigation revealed a reduction in the surface area of both hexagonal and star-shaped driver heads with an increase in the frequency of cycles. Notably, following all cycles, except 0-50 and 50-100, the alterations in the surface area of the star-shaped driver head were significantly greater than those observed in the hexagonal driver head (P < 0.001).

conclusionThe study shows that the star-shaped driver head deformed more than the hexagonal one, especially in cycles exceeding 100.

Indexed as

Dental Implant-Abutment DesignDental ImplantsDental Prosthesis DesignDental Stress AnalysisHumansIn Vitro TechniquesMaterials TestingTorqueDental ImplantsDental implant-abutment designDental implantsScrew driver

Identifiers

PMID40369532
PMCPMC12079920

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.