[Biomechanical advantages of personalized Y-shaped plates in treatment of distal humeral intra-articular fractures].

Hao Yu, Jiachen Peng, Jibin Yang, Lidan Yang, Zhi Xu, Chen Yang

Abstract readComparative StudyEnglish AbstractEnglish Abstract
In one paragraph

Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hao YuDepartment of Orthopedics, Affiliated Hospital of Zunyi Medical University, Zunyi Guizhou, 563000, P. R. China.
Jiachen PengDepartment of Orthopedics, Affiliated Hospital of Zunyi Medical University, Zunyi Guizhou, 563000, P. R. China.
Jibin YangDepartment of Orthopedics, Affiliated Hospital of Zunyi Medical University, Zunyi Guizhou, 563000, P. R. China.
Lidan YangDepartment of Orthopedics, Affiliated Hospital of Zunyi Medical University, Zunyi Guizhou, 563000, P. R. China.
Zhi XuDepartment of Orthopedics, Zhangjiagang Fifth People's Hospital, Zhangjiagang Jiangsu, 215600, P. R. China.
Chen YangCollege of Sports and Health, Shandong Sports University, Ji'nan Shandong, 250100, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To compare the biomechanical properties of personalized Y-shaped plates with horizontal plates, vertical plates, and traditional Y-shaped plates in the treatment of distal humeral intra-articular fractures through finite element analysis, and to evaluate their potential for clinical application. Methods: The study selected a 38-year-old male volunteer and obtained a three-dimensional model of the humerus by scanning his upper limbs using a 64-slice spiral CT. Four types of fracture-internal fixation models were constructed using Mimics 19.0, Geomagic Wrap 2017, Creo 6.0, and other software: horizontal plates, vertical plates, traditional Y-shaped plate, and personalized Y-shaped plate. The models were then meshed using Hypermesh 14.0 software, and material properties and boundary conditions were defined in Abaqus 6.14 software. AnyBody 7.3 software was used to simulate elbow flexion and extension movements, calculate muscle strength, joint forces, and load torques, and compare the peak stress and maximum displacement of the four fixation methods at different motion angles (10°, 30°, 50°, 70°, 90°, 110°, 130°, 150°) during elbow flexion and extension. Results: Under dynamic loading during elbow flexion and extension, the personalized Y-shaped plate exhibits significant biomechanical advantages. During elbow flexion, the peak internal fixation stress of the personalized Y-shaped plate was (28.8±0.9) MPa, which was significantly lower than that of the horizontal plates, vertical plates, and traditional Y-shaped plate ( Conclusion: The personalized Y-shaped plate demonstrates excellent biomechanical performance in the treatment of distal humeral intra-articular fractures, with lower stress and displacement, providing more stable fixation effects.

Indexed as

Bone PlatesFracture Fixation, InternalHumeral Fractures, DistalIntra-Articular FracturesPrecision MedicineProsthesis DesignAdultBiomechanical PhenomenaComputer SimulationElbowElbow JointFinite Element AnalysisHealthy VolunteersHumansHumerusImaging, Three-Dimensionalbiomechanical propertiesDistal humerus fracturefinite element analysisinternal fixationY-shaped plate

Identifiers

PMID40368860
PMCPMC12091714

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.