Evidence map›Paper›PMID 40365447›Full record

ArticleJAC-antimicrobial resistance2025

Evaluation of the stability of tigecycline in elastomeric infusion devices used for outpatient parenteral antimicrobial therapy.

Zenaw T Wolie, Sean Unwin, Andrew Burke, Hayoung Won, Steven C Wallis, R Andrew Seaton, Mark Gilchrist, Jason A Roberts, Fekade B Sime

Abstract read
In one paragraph

Article in JAC-antimicrobial resistance, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Zenaw T WolieFaculty of Medicine, Centre for Clinical Research, The University of Queensland, Building 71/918 RBWH Herston, Brisbane, Queensland 4029, Australia.
Sean UnwinInfection Management Services, Metro South Health, Princess Alexandra Hospital, Brisbane, Queensland, Australia.
Andrew BurkeFaculty of Medicine, Centre for Clinical Research, The University of Queensland, Building 71/918 RBWH Herston, Brisbane, Queensland 4029, Australia.ORCID https://orcid.org/0000-0002-2742-1556
Hayoung WonFaculty of Medicine, Centre for Clinical Research, The University of Queensland, Building 71/918 RBWH Herston, Brisbane, Queensland 4029, Australia.
Steven C WallisFaculty of Medicine, Centre for Clinical Research, The University of Queensland, Building 71/918 RBWH Herston, Brisbane, Queensland 4029, Australia.ORCID https://orcid.org/0000-0002-2392-9854
R Andrew SeatonDepartment of Infectious Diseases, Queen Elizabeth University Hospital, Glasgow, UK.
Mark GilchristOPAT Initiative, British Society for Antimicrobial Chemotherapy (BSAC), Birmingham, UK.ORCID https://orcid.org/0009-0003-0625-3535
Jason A RobertsFaculty of Medicine, Centre for Clinical Research, The University of Queensland, Building 71/918 RBWH Herston, Brisbane, Queensland 4029, Australia.
Fekade B SimeFaculty of Medicine, Centre for Clinical Research, The University of Queensland, Building 71/918 RBWH Herston, Brisbane, Queensland 4029, Australia.ORCID https://orcid.org/0000-0003-4061-2063

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Tigecycline is increasingly being considered in outpatient parenteral antimicrobial therapy (OPAT) programmes given its spectrum of activity; however, stability data are lacking, necessitating further study. Objective: To assess tigecycline stability in elastomeric infusers under OPAT conditions, following the UK Yellow Cover Document (YCD) stability testing guidelines. Methods: Tigecycline was reconstituted with normal saline in Leventon Dosi-Fuser and Baxter-LV10 infusers at doses of 50, 100 and 200 mg in 240 mL. Additionally, a tigecycline intermittent infusion dose (50 mg/100 mL) was reconstituted in Baxter-SV100 infusers. The infusers were stored under refrigerated storage (2°C-8°C) for 7 days, followed by exposure at an in-use temperature of 32°C for 24 h, or at 25°C for 2 hours for the intermittent infusion. Stability was evaluated using a stability-indicating assay, pH measurement, subvisible particle count and visual inspection as per the YCD. Results: After 7 days of refrigeration followed by 24 h exposure to 32°C, the mean ± SD percentage of tigecycline remaining was 97.9 ± 0.6, 97.3 ± 0.6 and 95.4 ± 0.8 for the Baxter LV10 devices, and 97.2 ± 0.3, 96.9 ± 0.5 and 95.8 ± 0.8 for Dosi-Fuser devices at the low, intermediate, and high dose levels, respectively. For intermittent infusion in Baxter-SV100 devices, the mean ± SD percentage remaining after 7 days of refrigerated storage followed by 2 h at 25°C was 99.7 ± 0.2. Conclusions: Tigecycline meets the UK YCD criteria of ≤5% degradation limit, indicating its suitability for both intermittent and continuous 24-h infusion in OPAT programs.

Identifiers

PMID40365447
PMCPMC12070266

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.