Evidence map›Paper›PMID 40363450›Full record

ArticleMaterials (Basel, Switzerland)2025

The Effect of Ultrasonic Probes on the Ability to Inspect Adhesive Joints.

Jakub Kowalczyk

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Jakub KowalczykFaculty of Civil and Transport Engineering, Institute of Machines and Motor Vehicles, Poznan University of Technology, 60-965 Poznan, Poland.ORCID 0000-0003-3385-1429

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ultrasonic tests are widely used, both in laboratory and industrial settings, to assess the quality of joints, mainly welded joints. Studies are being carried out on the possibility of ultrasonic evaluation of adhesive joints. This study was conducted using signal analysis in the time and frequency domains. The ultrasonic probes used in the tests were selected on the basis of the properties of the test elements. For example, when testing welded joints, ultrasonic probes with a water delay line bounded by a thin diaphragm were used. Since adhesives have different acoustic properties, it is necessary to evaluate the capabilities of different ultrasonic probes to test adhesive joints. Tests were conducted for two different adhesives (cyanoacrylate and structural) and eight ultrasonic probes with a frequency range of 1.660 to 13.70 MHz. In the literature, no studies have analyzed the use of ultrasonic probes at such different frequencies. Frequency has the greatest effect on the attenuation of ultrasonic waves and the ultrasonic wavelength, and it was noted that the adhesive could cause a 25 percent change in the maximum frequency of the ultrasonic pulse. It was also found that it is necessary to make reference samples before ultrasonic testing of adhesive joints, since specific frequencies can produce erroneous signals for the selected adhesives.

Indexed as

adhesivenondestructive testingultrasonic probeultrasonic testing

Identifiers

PMID40363450
PMCPMC12072572

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.