Evidence map›Paper›PMID 40363280›Full record

ArticleSensors (Basel, Switzerland)2025

A Full-Profile Measurement Method for an Inner Wall with Narrow-Aperture and Large-Cavity Parts Based on Line-Structured Light Rotary Scanning.

Zhengwen Li, Changshuai Fang, Xiaodong Zhang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Zhengwen LiState Key Laboratory of Precision Measuring Technology & Instruments, Laboratory of Micro/Nano Manufacturing Technology, Tianjin University, Tianjin 300072, China.ORCID 0009-0007-4486-0386
Changshuai FangState Key Laboratory of Precision Measuring Technology & Instruments, Laboratory of Micro/Nano Manufacturing Technology, Tianjin University, Tianjin 300072, China.
Xiaodong ZhangState Key Laboratory of Precision Measuring Technology & Instruments, Laboratory of Micro/Nano Manufacturing Technology, Tianjin University, Tianjin 300072, China.

Funding

National Natural Science Foundation of China 52405508National Natural Science Foundation of China 62373274National Program of China J0017-2326-QT
6 · The paper itself

Abstract

As a special component, inner-wall-shaped parts with a narrow aperture and large cavity play an important role in the field of industrial manufacturing. It is of great significance to accurately measure the full profile of the inner surface of such parts. Line-structured light scanning is a widely used method for inner wall 3D measurement, which is usually applied to linear scanning measurements of the inner wall of pipe-shaped parts. In view of the structural characteristics of narrow-aperture and large-cavity parts, this article establishes a multi-sensor scanning measurement system based on the principle of line-structured light, which adopts rotary scanning instead of the traditional linear scanning measurement method in the system. Additionally, a calibration method is introduced to resolve the challenges associated with the calibration of rotation axis parameters. Considering the structural constraints in the measurement of narrow-aperture and large-cavity parts, a structural optimization algorithm is designed to enable the sensor to achieve a high theoretical measurement resolution while satisfying the geometric constraints of the measured parts. In order to minimize the size of the sensor, the adjacent sub-sensors in the system are arranged in the form of low overlapping fields of view (FOV). To solve the problem of multi-sensor registration under low overlapping FOV, a calibration method based on the structural characteristics of the measurement system itself is proposed, which realizes low-cost and high-precision calibration of the multi-sensor system. Through the repeatability measurement experiment of the spherical cavity parts, the average measurement deviation of the spherical cavity radius was measured to be 6 μm, and the standard deviation was 11.4 μm, which verified the feasibility of the measurement system proposed in this article. By comparing the system calibration method proposed in this article with existing methods, the measurement accuracy of the system is improved by approximately 80%, demonstrating the effectiveness of the proposed method.

Indexed as

line-structured lightmulti-sensor registrationrotary scanning

Identifiers

PMID40363280
PMCPMC12074176

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.