Evidence map›Paper›PMID 40363154›Full record

ArticleSensors (Basel, Switzerland)2025

Personalizing Seizure Detection for Individual Patients by Optimal Selection of EEG Signals.

Rosanna Ferrara, Martino Giaquinto, Gennaro Percannella, Leonardo Rundo, Alessia Saggese

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Rosanna FerraraDepartment of Information Engineering, Electrical Engineering and Applied Mathematics (DIEM), University of Salerno, 84084 Fisciano, Italy.ORCID 0000-0001-7543-4848
Martino GiaquintoDepartment of Information Engineering, Electrical Engineering and Applied Mathematics (DIEM), University of Salerno, 84084 Fisciano, Italy.ORCID 0000-0001-5010-3604
Gennaro PercannellaDepartment of Information Engineering, Electrical Engineering and Applied Mathematics (DIEM), University of Salerno, 84084 Fisciano, Italy.ORCID 0000-0002-1227-0353
Leonardo RundoDepartment of Information Engineering, Electrical Engineering and Applied Mathematics (DIEM), University of Salerno, 84084 Fisciano, Italy.ORCID 0000-0003-3341-5483
Alessia SaggeseDepartment of Information Engineering, Electrical Engineering and Applied Mathematics (DIEM), University of Salerno, 84084 Fisciano, Italy.ORCID 0000-0003-4687-7994

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electroencephalography is a widely used non-invasive method for monitoring brain electrical activity, critical for diagnosing and managing neurological disorders such as epilepsy. While clinical standards use 21 electrodes to capture comprehensive neural signals, a personalized approach can enhance performance by selecting patient-specific channels, reducing noise and redundancy. This study introduces an innovative, lightweight deep learning system optimized for real-time seizure detection in personalized wearable devices. The system uses an efficient Convolutional Neural Network that processes data from just two channels. These channels are automatically selected using a data-driven mechanism that identifies the most informative scalp regions based on each patient's unique seizure patterns. The proposed approach ensures high reliability, even with small datasets, and improves interpretability for clinicians by overcoming the limitations of more complex methods. The tailored channel selection boosts detection accuracy and ensures robust performance across different seizure types while reducing the computational burden typical of multi-electrode systems. Validation on the publicly available CHB-MIT dataset achieved an average balanced accuracy of 0.83 and a false-positive rate of approximately 0.1/h. The system's performance matches, and in some cases outperforms, state-of-the-art systems that use four fixed channels in temporal regions, demonstrating the potential of two-channel wearable solutions, specifically with a non-negligible 30% reduction in the false-positive rate. This interpretable, patient-specific method enables the development of personalized, efficient, and compact wearable devices for reliable seizure detection in everyday life.

Indexed as

ElectroencephalographyPrecision MedicineSeizuresAlgorithmsDeep LearningEpilepsyHumansNeural Networks, ComputerSignal Processing, Computer-AssistedWearable Electronic Deviceschannel selectionEEG analysislightweight CNNpersonalized medicineseizure detectionwearable systems

Identifiers

PMID40363154
PMCPMC12074425

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.