ArticleSensors (Basel, Switzerland)2025
A Novel Grouting Diffusion Monitoring System Based on ZigBee Wireless Sensor Network.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Optimization of the ZigBee Routing Algorithm for the Beidou Sugar Beet Environmental Monitoring System.Sensors (Basel, Switzerland) · 2026Article
- An Enhanced ZigBee-Based Indoor Localization Method Using Multi-Stage RSSI Filtering and LQI-Aware MLE.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Grouting technology is widely used in construction and civil engineering, where evaluating grouting effectiveness is crucial due to the uncertainty of subsurface conditions. Existing methods face drawbacks such as destructiveness, high cost, poor durability, and limited data collection. To address these issues, this paper proposes a novel wireless real-time monitoring system based on a ZigBee sensor network framework. The sensor system integrates a direct current method in geophysics with apparent resistivity measurement to assess grouting effectiveness in real time. It consists of multichannel data acquisition units with electrodes for sensing underground currents and a user control unit for centralized management and data processing. A system acquisition performance test confirmed that the differential input channel's equivalent input noise of the ADC was only 175 μV and 188 μV, and the average error of the captured sine wave data was 4.51 mV and 4.19 mV, ensuring the voltage measurement accuracy of the data acquisition units. Stability testing of the equipment in road and construction environments showed an average RSD of 2.86% and 2.92%, respectively, indicating good stability of the measurements. ZigBee network performance tests in three simulated environments and a field test showed that the packet loss rate (PLR) was less than 2% from 0 to 50 m, ensuring network communication in grouting project scenarios. On-site experiments demonstrate that the system can simultaneously monitor multiple profiles and perform inversions in the grouting area, which can be assembled into 3D inversion images for evaluating grout diffusion, offering valuable insights for optimizing construction operations, and enhancing grouting efficiency.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.