Evidence map›Paper›PMID 40363088›Full record

ArticleSensors (Basel, Switzerland)2025

PatchCTG: A Patch Cardiotocography Transformer for Antepartum Fetal Health Monitoring.

M Jaleed Khan, Manu Vatish, Gabriel Davis Jones

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

M Jaleed KhanOxford Digital Health Labs, Nuffield Department of Women's & Reproductive Health (NDWRH), University of Oxford, Women's Centre (Level 3), John Radcliffe Hospital, Oxford OX3 9DU, UK.ORCID 0000-0003-4727-4722
Manu VatishOxford Digital Health Labs, Nuffield Department of Women's & Reproductive Health (NDWRH), University of Oxford, Women's Centre (Level 3), John Radcliffe Hospital, Oxford OX3 9DU, UK.ORCID 0000-0002-6012-2574
Gabriel Davis JonesOxford Digital Health Labs, Nuffield Department of Women's & Reproductive Health (NDWRH), University of Oxford, Women's Centre (Level 3), John Radcliffe Hospital, Oxford OX3 9DU, UK.ORCID 0000-0003-4070-4814

Funding

UK Research and Innovation MR/X029689/1
6 · The paper itself

Abstract

Antepartum Cardiotocography (CTG) is a biomedical sensing technology widely used for fetal health monitoring. While the visual interpretation of CTG traces is highly subjective, with the inter-observer agreement as low as 29% and a false positive rate of approximately 60%, the Dawes-Redman system provides an automated approach to fetal well-being assessments. However, it is primarily designed to rule out adverse outcomes rather than detect them, resulting in a high specificity (90.7%) but low sensitivity (18.2%) in identifying fetal distress. This paper introduces PatchCTG, an AI-enabled biomedical time series transformer for CTG analysis. It employs patch-based tokenisation, instance normalisation, and channel-independent processing to capture essential local and global temporal dependencies within CTG signals. PatchCTG was evaluated on the Oxford Maternity (OXMAT) dataset, which comprises over 20,000 high-quality CTG traces from diverse clinical outcomes, after applying the inclusion and exclusion criteria. With extensive hyperparameter optimisation, PatchCTG achieved an AUC of 0.77, with a specificity of 88% and sensitivity of 57% at Youden's index threshold, demonstrating its adaptability to various clinical needs. Its robust performance across varying temporal thresholds highlights its potential for both real-time and retrospective analysis in sensor-driven fetal monitoring. Testing across varying temporal thresholds showcased it robust predictive performance, particularly with finetuning on data closer to delivery, achieving a sensitivity of 52% and specificity of 88% for near-delivery cases. These findings suggest the potential of PatchCTG to enhance clinical decision-making in antepartum care by providing a sensor-based, AI-driven, objective tool for reliable fetal health assessment.

Indexed as

CardiotocographyFetal MonitoringFemaleHeart Rate, FetalHumansPregnancySignal Processing, Computer-Assistedantepartumbiomedical time seriescardiotocographyfetal healthtransformer

Identifiers

PMID40363088
PMCPMC12074329

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.