Evidence map›Paper›PMID 40360696›Full record

ArticleScientific reports2025

Exploring the efficacy of combination of point-of-use filters and peracetic acid disinfection in reducing total viable counts in final rinse water of endoscopes.

Xiongjing Cao, Hua Meng, Longbiao Cai, Yunzhou Fan, Fang Gao, Yanyan Wu, Huangguo Xiong, Lijuan Xiong

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xiongjing Cao *Department of Nosocomial Infection Management, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 JieFang Avenue, Wuhan, 430022, China.
Hua Meng *Department of Nosocomial Infection Management, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 JieFang Avenue, Wuhan, 430022, China.
Longbiao Cai *Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
Yunzhou FanDepartment of Nosocomial Infection Management, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 JieFang Avenue, Wuhan, 430022, China.
Fang GaoDepartment of Nosocomial Infection Management, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 JieFang Avenue, Wuhan, 430022, China.
Yanyan WuDepartment of Nosocomial Infection Management, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 JieFang Avenue, Wuhan, 430022, China.
Huangguo XiongDepartment of Nosocomial Infection Management, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 JieFang Avenue, Wuhan, 430022, China.
Lijuan XiongDepartment of Nosocomial Infection Management, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 JieFang Avenue, Wuhan, 430022, China. lijuanxiong2016@126.com.

Funding

Xiongjing Cao F016010032200318706
6 · The paper itself

Abstract

The final rinse water pollution of endoscopes in medical institutions is a severe growing problem, posing a latent risk to nosocomial infection. This study aimed to explore the efficacy of combination of point-of-use (POU) filters and peracetic acid (PAA) disinfection in reducing total viable counts (TVCs) in final rinse water of endoscopes. Eight final rinse water faucets of endoscope centers were randomly selected and none of the faucets had POU filters prior to the study. Four faucets were assigned to experimental group and had POU filters installed, the other four faucets were set as control group and did not have POU filters installed. During monitoring, both the experimental and control groups were used 0.3% PAA to disinfect the purified water system twice. TVCs in final rinse water was monitored weekly for 13 weeks. 231 final rinse water samples were collected, of which 111 and 120 samples were in the experimental and control groups, respectively. The mean TVCs and positive rate of samples for experimental group were both significantly lower than that of control group [10 vs. 50,450 colony-forming units (CFU)/100 mL, and 27.7% vs. 98.3%, P < 0.001]. The TVCs in control group was from 2.0 × 10

Indexed as

DisinfectantsDisinfectionEndoscopesFiltrationPeracetic AcidWater MicrobiologyColony Count, MicrobialCross InfectionHumansWater PurificationDisinfectantsPeracetic AcidCombinationEndoscope centerPeracetic acid disinfectionPoint-of-use filtrationTotal viable counts

Identifiers

PMID40360696
PMCPMC12075860

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.