ArticleMikrochimica acta2025
Bright nanoparticle-labeled lateral flow immunoassay for rapid quantitative detection of tacrolimus in human plasma.
Article in Mikrochimica acta, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Point-of-Care Test to Measure Tacrolimus Directly from Unprocessed Whole Blood.Analytical chemistry · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Tacrolimus (Tac), a macrolide immunosuppressant widely employed in organ transplantation, requires therapeutic drug monitoring owing to the narrow treatment window. In this study, we established an innovative ultrabright nanoparticle-based lateral flow immunoassay (LFIA) for one-step rapid quantitative detection of Tac in human plasma. The aggregation-induced emission (AIE) luminogen, AIE490, was embedded in polystyrene nanoparticles to assemble the ultrabright AIE490NP as a highly sensitive fluorescence marker. Carboxyl-modified Tac was used to couple with carrier proteins to synthesize complete antigens coated on the test line. Under optimized conditions, the limit of detection for Tac is 0.589 ng/mL in human plasma. The linear range was 1-1000 ng/mL, completely covering the safe plasma concentration of Tac, 5-15 ng/mL. The intra- and inter-assay precisions of the established method are below 17.99% and 19.94%, respectively. In addition, for measuring the plasma concentration of Tac in 139 clinical samples, the results of the LFIA are consistent with those of LC-MS/MS (R
Indexed as
Identifiers
40358770What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.