Evidence map›Paper›PMID 40357224›Full record

ArticleRisk management and healthcare policy2025

The Application of Multifunctional Endoscope Transport Carts in Bedside Endoscopy in Intensive Care Unit Patients.

Miao Zhang, Jiang Du, Qiongying Zhang, Fu Qiao, Liansong Ye, Bing Hu, Siyuan Tao

Abstract read
In one paragraph

Article in Risk management and healthcare policy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Miao Zhang *Department of Gastroenterology and Hepatology, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China.
Jiang Du *Department of Gastroenterology and Hepatology, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China.
Qiongying ZhangDepartment of Gastroenterology and Hepatology, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China.
Fu QiaoDepartment of Infection Control, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China.
Liansong YeDepartment of Gastroenterology and Hepatology, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China.
Bing HuDepartment of Gastroenterology and Hepatology, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China.
Siyuan TaoDepartment of Infection Control, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: This study aimed to investigate whether the application of multifunctional endoscope transport carts, in bedside endoscopy in intensive care unit (ICU) patients, can improve the cleaning quality of the endoscopes. Methods: A total of 175 endoscopes, used for bedside endoscopy in ICU patients in a hospital in China during November 2023 to January 2024, were randomly classified into the control group (n=88) and the experimental group (n=87). Multifunctional transport carts were used to deliver the endoscopes in the experimental group and traditionally used transport trolleys were used in the control group. Adenosine triphosphate (ATP) tests were performed to measure the relative light unit (RLU) values for the outer surfaces and forceps channels of the endoscopes, and a satisfaction survey was conducted with nurses who used the endoscope transport trolleys/carts and the endoscope cleaning staff. Results: The ATP values for the outer surfaces and forceps channels of the endoscopes in the experimental group were 10.0 (6.0, 17.0) RLU and 7.0 (4.0, 11.0) RLU, respectively, lower than 33.5 (9.3, 77.0) RLU for outer surfaces and 14.0 (5.0, 39.8) RLU for forceps channels in the control group. The pass rates for cleaning quality of the outer surfaces and channels of the endoscopes in the experimental group were 98.9% and 100%, respectively, higher than 88.6% for outer surfaces and 93.2% for channels in the control group ( Conclusion: The application of multifunctional endoscope transport carts in bedside endoscopy in ICU patients could improve the quality of endoscope cleaning.

Indexed as

adenosine triphosphate testbedside endoscopyintensive care unittransport carts

Identifiers

PMID40357224
PMCPMC12067975

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.