Evidence map›Paper›PMID 40356796›Full record

ArticleERJ open research2025

Artificial intelligence-based echocardiography assessment to detect pulmonary hypertension.

Mahan Salehi, Samer Alabed, Michael Sharkey, Ahmed Maiter, Krit Dwivedi, Tarik Yardibi, Mona Selej, Abdul Hameed, Athanasios Charalampopoulos, David G Kiely and 1 more

Abstract read
In one paragraph

Article in ERJ open research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Review
  6. Article
  7. [Role of echocardiography in the assessment of right ventricular function in pulmonary hypertension].Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences · 2026
    Review
  8. Article
  9. Review
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Mahan SalehiDepartment of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK.
Samer AlabedDepartment of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK.ORCID https://orcid.org/0000-0002-9960-7587
Michael SharkeyDepartment of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK.
Ahmed MaiterDepartment of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK.
Krit DwivediDepartment of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK.
Tarik YardibiJanssen Research & Development, LLC, Raritan, NJ, USA.
Mona SelejJanssen Research & Development, LLC, Raritan, NJ, USA.
Abdul HameedDepartment of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK.ORCID https://orcid.org/0000-0002-2128-2081
Athanasios CharalampopoulosDepartment of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK.
David G KielyDepartment of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK.ORCID https://orcid.org/0000-0003-0184-6502
Andrew J SwiftDepartment of Infection, Immunity and Cardiovascular Disease, University of Sheffield, Sheffield, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Tricuspid regurgitation jet velocity (TRJV) on echocardiography is used for screening patients with suspected pulmonary hypertension (PH). Artificial intelligence (AI) tools, such as the US2.AI, have been developed for automated evaluation of echocardiograms and can yield measurements that aid PH detection. This study evaluated the performance and utility of the US2.AI in a consecutive cohort of patients with suspected PH. Methods: 1031 patients who had been investigated for suspected PH between 2009-2021 were retrospectively identified from the ASPIRE registry. All patients had undergone echocardiography and right heart catheterisation (RHC). Based on RHC results, 771 (75%) patients with a mean pulmonary arterial pressure >20 mmHg were classified as having a diagnosis of PH (as per the 2022 European guidelines). Echocardiograms were evaluated manually and by the US2.AI tool to yield TRJV measurements. Results: The AI tool demonstrated high interpretation yield, successfully measuring TRJV in 87% of echocardiograms. Manually and automatically derived TRJV values showed excellent agreement (intraclass correlation coefficient 0.94, 95% CI 0.94-0.95) with minimal bias (Bland-Altman analysis). Automated TRJV measurements showed equally high diagnostic accuracy for PH as manual measurements (area under the curve 0.88, 95% CI 0.84-0.90 Conclusion: Automated TRJV measurements on echocardiography were similar to manual measurements, with similarly high and noninferior diagnostic accuracy for PH. These findings demonstrate that automated measurement of TRJV on echocardiography is feasible, accurate and reliable and support the implementation of AI-based approaches to echocardiogram evaluation and diagnostic imaging for PH.

Identifiers

PMID40356796
PMCPMC12067425

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.