Observational studyKorean journal of ophthalmology : KJO2025
Effect of 50-Hz Filters on Pattern Electroretinogram.
Observational study in Korean journal of ophthalmology : KJO, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposePattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
methodsThis is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
resultsA total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
conclusionsAlthough peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials