ArticlePacing and clinical electrophysiology : PACE2025

Noninvasive Impedance Analysis During S-ICD Insertion Provides Justification for Defibrillation Based Testing Deferment.

Andreas G Kontopidis, Mark É Czeisler, David H Yoo, Olivia Whittaker, Daniel C Pipilas, Theofanie Mela

Abstract read
In one paragraph

Article in Pacing and clinical electrophysiology : PACE, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Andreas G KontopidisBoston Scientific, Marlborough, Massachusetts, USA.ORCID 0009-0008-5999-5459
Mark É CzeislerHarvard Medical School, Boston, Massachusetts, USA.
David H YooHarvard Medical School, Boston, Massachusetts, USA.ORCID 0000-0002-6793-3767
Olivia WhittakerTufts University School of Medicine, Boston, Massachusetts, USA.
Daniel C PipilasHarvard Medical School, Boston, Massachusetts, USA.
Theofanie MelaHarvard Medical School, Boston, Massachusetts, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFollowing subcutaneous implantable cardioverter-defibrillator (S-ICD) insertion, induction of ventricular fibrillation (VF) and defibrillation threshold testing (DFT) is the standard of practice to assess system performance. In contrast, DFT testing is not routinely performed after transvenous ICD (T-ICD) insertion, supported by literature that emphasizes negative clinical repercussions and reliability of noninvasive predictors of successful defibrillation. There is a paucity of data for both the trajectory of noninvasive low voltage (LV) impedance measurements at S-ICD insertion through the time of potential DFT testing and for the proximity of LV impedance measurements and high voltage (HV) shock impedance from 65J DFT or 10J testing.

objectiveWe aim to characterize the trend in LV impedance from initial S-ICD connection (LV T0) to final intraprocedural impedance (LV T4) and to compare LV impedance with HV impedance.

methodsData from patients who underwent S-ICD implantation between July 2022 and March 2024 were analyzed. LV impedance measurements were collected during implant and HV impedance measurements were collected if 65J DFT/10J testing was performed. Differences in mean impedances at each time point were evaluated using paired t-tests. For those who underwent 10J or 65J DFT testing, LV impedance was compared with HV impedance.

resultsThe primary analytic sample included 53 patients, with a mean age of 51 ± 15.7 years; 16 (30.2%) were female. LV impedance decreased by a mean of 14.5 ± 9.8 ohms (18.3%; p <0.001) from S-ICD connection (T0) to the final intraprocedural measurement, approximately 60 min postimplant (T4). Among 35 patients who underwent HV testing (65J DFT or 10J), LV impedance at T4 and HV impedance did not differ significantly (1.7 ± 6.3 ohms; p = 0.116).

conclusionOur findings demonstrate a predictable reduction in LV impedance from S-ICD connection to subsequent intraprocedural measurements. We also found that LV impedance at LV T4, the final intraprocedural measurement, did not significantly differ from contemporaneous HV impedance. Together, these findings indicate that LV impedance at implant can be expected to decline, and that 60-min postimplant LV impedance may reliably approximate HV impedance. Evaluation of circumstances in which LV impedance could influence the decision to perform DFT testing is warranted.

Indexed as

Cardiography, ImpedanceDefibrillators, ImplantableElectric ImpedanceVentricular FibrillationAgedFemaleHumansMaleMiddle AgedRetrospective Studies

Identifiers

PMID40356268
PMCPMC12166533

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.