ArticleJournal of the American Medical Informatics Association : JAMIA2026
Dependence of premature ventricular complexes on heart rate-it's not that simple.
Article in Journal of the American Medical Informatics Association : JAMIA, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
objectiveFrequent premature ventricular complexes (PVCs) can lead to adverse health conditions such as cardiomyopathy. The linear correlation between PVC frequency and heart rate (as positive, negative, or neutral) on a 24-hour Holter recording has been proposed as a way to classify patients and guide treatment with beta-blockers. Our objective was to evaluate the robustness of this classification to measurement methodology, different 24-hour periods, and nonlinear dependencies of PVCs on heart rate. MATERIALS AND
methodsWe analyzed 82 multi-day Holter recordings (1-7 days) collected from 48 patients with frequent PVCs (burden 1%-44%). For each record, linear correlation between PVC frequency and heart rate was computed for different 24-hour periods and using different length intervals to determine PVC frequency.
resultsUsing a 1-hour interval, the correlation between PVC frequency and heart rate was consistently positive, negative, or neutral on different days in only 36.6% of patients. Using shorter time intervals, the correlation was consistent in 56.1% of patients. Shorter time intervals revealed nonlinear and piecewise linear relationships between PVC frequency and heart rate in many patients. DISCUSSION: The variability of the correlation between PVC frequency and heart rate across different 24-hour periods and interval durations suggests that the relationship is neither strictly linear nor stationary. A better understanding of the mechanism driving the PVCs, combined with computational and biological models that represent these mechanisms, may provide insight into the observed nonlinear behavior and guide more robust classification strategies.
conclusionLinear correlation as a tool to classify patients with frequent PVCs should be used with caution. It is sensitive to the specific 24-hour period analyzed and the methodology used to segment the data. More sophisticated classification approaches that can capture nonlinear and time-varying dependencies should be developed and considered in clinical practice.