ArticleCureus2025
Comparison of 3M Reston™ Self-Adhesive Foam Pad and 3M Microfoam™ Surgical Tape in Preventing Nasal Pressure Injuries Associated With Nasotracheal Intubation: A Randomized Controlled Trial.
Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundNasotracheal intubation (NTI) is widely used in dental and maxillofacial surgeries to secure the airway while maintaining an unobstructed surgical field. However, NTI is associated with complications such as nasal bleeding, bacteremia, and retropharyngeal perforation. Among these, medical device-related pressure injuries (MDRPIs) caused by nasotracheal tubes are a significant concern. These injuries range from erythema to severe necrosis and can lead to postoperative pain, aesthetic concerns, and prolonged treatment. 3M Microfoam™ surgical tape (3MM; 3M Japan Limited, Shinagawa-ku, Tokyo) has been shown to effectively reduce the risk of nasal pressure injuries. However, its direct application to the skin can irritate, limiting its use in patients with sensitive skin. 3M Reston™ self-adhesive foam pads (3MR; 3M Japan Limited) are constructed using a breathable sponge designed to distribute pressure evenly. They are applied to the medical device rather than directly to the skin. This study aimed to compare the effectiveness of 3MR and 3MM in preventing nasal pressure injuries during NTI.
methodsA randomized, double-blind prospective study was conducted with 144 patients who underwent general anesthesia with NTI for oral and maxillofacial surgery. Patients were randomly assigned to receive nasal alar protection with either 3MR or 3MM, both of which were attached to the endotracheal tube. The primary outcome was the incidence of nasal pressure injuries. These were classified as tube imprint, tube-induced erythema, and protective material-induced erythema. Those with no nasal pressure injuries constituted a fourth group classed as no imprint or erythema. The secondary outcomes were the pressure between the tube and the nasal alar (PTN) and the difference between the nostril diameter and the outer diameter of the intubation tube.
resultsAmong the 140 patients analyzed, the proportion of patients with no imprint or erythema was higher in the 3MR (45 patients) than the 3MM (33 patients) group. The incidence of tube-induced erythema was lower in the 3MR group, but protective material-induced erythema was slightly higher in the 3MM group. However, the differences between the groups were not statistically significant (p = 0.66). The median PTN was 51 (30.1-75.9) g in the 3MR group and 58.1 (36.1-116.8) g in the 3MM group, which was not a significant difference (p = 0.08). The difference between nostril diameter and the outer diameter of the intubation tube was similar in both groups (p = 0.73).
conclusionAlthough no statistically significant differences between the 3MR and 3MM groups were observed in this study, the 3MR group showed a tendency to fewer pressure injuries and better pressure distribution. Given the importance of even pressure distribution to the prevention of MDRPIs, 3MR may be a moderately better alternative to 3MM for patients at high risk of nasal pressure injuries. Further studies with larger sample sizes and long-term follow-up are necessary to fully evaluate the clinical benefits of 3MR.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.