Evidence map›Paper›PMID 40351646›Full record

ArticleJournal of orthopaedic case reports2025

Functional Outcome of Distal Radius Fractures Managed by Minimally Invasive Plate Osteosynthesis: A Prospective Study of 20 Patients.

Ashwini Dondapati, Haemanath Pandian, Sheik Mohideen, E Pradeep, K V Arun Kumar, P Balamurugan

Abstract read
In one paragraph

Article in Journal of orthopaedic case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ashwini DondapatiDepartment of Orthopaedic Surgery, Chettinad Hospital and Research Institute, Kelambakkam, Tamil Nadu, India.
Haemanath PandianDepartment of Orthopaedic Surgery, Sree Balaji Medical College And Hospital , Chromepet, Chennai, Tamil Nadu 600044.
Sheik MohideenDepartment of Orthopaedic Surgery, Chettinad Hospital and Research Institute, Kelambakkam, Tamil Nadu, India.
E PradeepDepartment of Orthopaedic Surgery, Chettinad Hospital and Research Institute, Kelambakkam, Tamil Nadu, India.
K V Arun KumarDepartment of Orthopaedic Surgery, Chettinad Hospital and Research Institute, Kelambakkam, Tamil Nadu, India.
P BalamuruganDepartment of Orthopaedics and Traumatology, Tagore Medical College and Hospital. Rathinamangalam, Chennai.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: A distal radius fracture is a common injury that affects people of all ages. However, there are various therapy approaches that are controversial. Casting with or without closed reduction has long been considered a feasible option for treating distal radius fractures; alternative options include K-wire fixation and ligamentotax are with external fixation. However, with limited function and impairments, the results are frequently poor. "Several studies have found that distal radius fractures treated with external fixation have good anatomical and functional outcomes, although there is a substantial risk of pin tract infection and nerve damage. Internal fixation and classic open reduction frequently result in severe soft tissue dissection and periosteal damage, which can cause infection, delayed union, and non-union. Fortunately, a new approach known as minimally invasive plate osteosynthesis (MIPO) has recently evolved, which can reduce soft tissue stripping and bone vascularity loss while improving fracture healing. Materials and Methods: A prospective study of 20 patients with closed distal radius fractures was treated by the MIPO technique with a palmar locking plate between November 2022 and April 2023 and was followed up for 6 months. Results: There were 12 females and 8 males with an average age of 54.2 years. The average blood loss was around 52 ml approximately. 11 patients obtained excellent results, 7 cases had good results and 2 patients had moderate effects. The average disabilities of the arm, shoulder, and hand score after 6 months was about 10.2. Conclusion: In conclusion, two small incisions to implant a palmar locking plate by MIPO for distal radius fractures give good functional results as soft tissue handling is better compared to the conventional method of plating. But further research also should be carried out to explore more suitable treatment for specific individuals.

Indexed as

and hand scoredisabilities of the armDistal radius fractureminimally invasive plate fixationpalmar locking plateshoulder

Identifiers

PMID40351646
PMCPMC12064226

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.