Evidence map›Paper›PMID 40347045›Full record

ArticleClinical implant dentistry and related research2025

Enhancing Implant Prosthodontics: In Vitro Accuracy of Coded Healing Abutments on the Edentulous Lower Jaw.

Boldizsár Vánkos, Dénes Palaszkó, Kata Kelemen, Anna Németh, Judit Schmalzl, Dániel Márk Zentai, Elek Dinya, Péter Hermann, Barbara Kispélyi

Abstract read
In one paragraph

Article in Clinical implant dentistry and related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Boldizsár VánkosDepartment of Prosthodontics, Semmelweis University, Budapest, Hungary.
Dénes PalaszkóDepartment of Prosthodontics, Semmelweis University, Budapest, Hungary.
Kata KelemenDepartment of Prosthodontics, Semmelweis University, Budapest, Hungary.
Anna NémethDepartment of Prosthodontics, Semmelweis University, Budapest, Hungary.
Judit SchmalzlDepartment of Prosthodontics, Semmelweis University, Budapest, Hungary.
Dániel Márk ZentaiDepartment of Prosthodontics, Semmelweis University, Budapest, Hungary.
Elek DinyaInstitute of Digital Health Sciences, Semmelweis University, Budapest, Hungary.
Péter HermannDepartment of Prosthodontics, Semmelweis University, Budapest, Hungary.
Barbara KispélyiDepartment of Prosthodontics, Semmelweis University, Budapest, Hungary.ORCID https://orcid.org/0000-0002-0530-0905

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to investigate the accuracy of conventional and digital impression-making and cast-fabrication using coded healing abutments on an edentulous mandibular model under in vitro conditions. MATERIALS AND

methodsOur study investigated the accuracy of the On1 Concept (Nobel Biocare; Kloten, Switzerland) coded healing abutment system using conventional and digital workflows. The Conical Connection (CC) system (Nobel Biocare; Kloten, Switzerland) was used as the control group in both workflows. 10-10 open-tray impressions and intraoral scans were made from the reference model with each system. Models built from intraoral scans were additively fabricated, and open-tray impressions were poured with type-4 dental stone. The prepared models were digitized using a desktop scanner with an accuracy of 4 μm (E4, 3Shape; Copenhagen, Denmark) and superimposed on the reference scan. Four linear distances and root mean square (RMS) deviations were measured using metrology software.

resultsFive dimensions were measured using signed and absolute deviations, resulting in nine outcomes. RMS and diagonal deviations provided the most insight into overall model deviations. Mean RMS deviations were: 58.30 (14.95) μm for CC_conv, 47.66 (13.04) μm for On1_conv, 204.97 (37.40) μm for CC_dig, and 136.64 (13.49) μm for On1_dig. Significant differences were found between On1_conv vs. CC_dig, On1_conv vs. On1_dig, and CC_conv vs. CC_dig. Mean linear deviations between the molar positions were: 24.49 (58.20) μm for CC_conv, 87.46 (106.70) μm for On1_conv, -104.76 (125.83) μm for CC_dig, and 140.64 (190.56) μm for On1_dig. Significant differences were observed between On1_conv vs. CC_dig and CC_dig vs. On1_dig.

conclusionsBased on the RMS deviations, the conventional method is significantly more accurate at both implant and platform levels in the case of an in vitro edentulous lower jaw model. The RMS deviations of the implant analogs are smaller on the platform level with both conventional and digital methods.

Indexed as

Dental AbutmentsDental Implant-Abutment DesignDental Impression TechniqueJaw, EdentulousComputer-Aided DesignHumansIn Vitro TechniquesMandibleModels, Dentaldental casting techniquedental implantationdental impression techniquemodelsprosthodontics

Identifiers

PMID40347045
PMCPMC12063562

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.