Evidence map›Paper›PMID 40346189›Full record

ArticleScientific reports2025

Finite element analysis of welded titanium bar and poly ether ether ketone bar in maxillary full arch splinted interim prosthesis.

Lamiaa Farouk Zaki Mohamed, Hebatallah Tarek Mohamed, Hany Ibrahim Eid, Soha Saeid Mohammed, Rana Mohammad Abdelrahman

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lamiaa Farouk Zaki MohamedOral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, 11561, Egypt.
Hebatallah Tarek MohamedOral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, 11561, Egypt.
Hany Ibrahim EidOral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, 11561, Egypt.
Soha Saeid MohammedOral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Organization of African Unity Street, Cairo, 11561, Egypt. sohasaeid@dent.asu.edu.eg.
Rana Mohammad AbdelrahmanOral and Maxillofacial Prosthodontics Department, School of Dentistry, Newgiza University, Giza, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Full arch fixed provisional restorations are prone to fracture during function for several reasons. Those types of fractures during the healing period eliminate the cross-arch stabilization and disrupt stress distribution patterns. FEA (Finite Element Analysis) study was carried out using edentulous maxillary models where implants and other components were represented in three dimensional (3D) geometric models. Two 3D FEA models with six implants were used. Model TB: the implants were splinted with welded titanium bar; Model PB: the implants were splinted with PEEK (Poly Ether Ether Ketone) bar. An interim full arch PMMA (Poly methyl methacrylate) prosthesis was virtually designed for both models. Both models were subjected to vertical and oblique forces with a single force magnitude of 100 N. The amount of maximum equivalent Von-Mises stresses was calculated at the cervical part of the bone cylinder (marginal bone) and both frameworks. Under bilateral vertical loading, stresses were found to be comparable at the marginal bone between titanium and PEEK splinting. The PEEK framework had better and lower stress distribution than the titanium. While under unilateral oblique forces PEEK had better mechanical response on the marginal bone. And PEEK framework itself showed higher stresses than the titanium. The behavior of PEEK and Titanium splints are comparable under the vertical bilateral load. On the contrary to the oblique load, where the stresses are higher within the PEEK splint that correspondingly transmit less stresses to the underlying structures. So, PEEK was found successful in regards to the pattern of stress distribution to both implants and marginal bone, but further studies are needed to confirm its effectiveness and broader applicability.

Indexed as

Finite Element AnalysisKetonesMaxillaPolyethylene GlycolsTitaniumBenzophenonesDental ImplantsDental Stress AnalysisHumansPolymersStress, MechanicalBenzophenonesDental ImplantsKetonespolyetheretherketonePolyethylene GlycolsPolymersTitanium

Identifiers

PMID40346189
PMCPMC12064776

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.