Influence of nozzle configurations on radiobiological effects in carbon ion radiation therapy estimated using GATE/Geant4.

Hermann Fuchs, Alessio Parisi, Keith M Furutani, Dietmar Georg, Chris J Beltran

Abstract read
In one paragraph

Article in Zeitschrift fur medizinische Physik, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hermann FuchsDepartment of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL, United States of America; Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria. Electronic address: hermann.fuchs@meduniwien.ac.at.
Alessio ParisiDepartment of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL, United States of America.
Keith M FurutaniDepartment of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL, United States of America. Electronic address: furutani.keith@mayo.edu.
Dietmar GeorgDepartment of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
Chris J BeltranDepartment of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL, United States of America.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCarbon Ion Radiation Therapy (CIRT) has been used in Europe and in Asia for several decades. The first treatment facility in America is now under construction at Mayo Clinic Florida (MCF) in Jacksonville. CIRT is known to have a variable relative biological effectiveness (RBE) which depends on the microdosimetric spectra and consequently the kinetic energy spectra. PURPOSE: CIRT centers from different vendors exist around the world with different accelerators, delivery, and nozzle designs. Although nominally they provide comparable energies and beam qualities, this study investigates how the different nozzle designs might affect radiation quality and the consequent RBE.

methodsThe impact of three nozzle designs, the upcoming MCF (Jacksonville, USA), MedAustron Ion Therapy Center (Wiener Neustadt, Austria), and the Osaka HIMAK (Osaka, Japan), on the RBE was investigated using OpenGATE10. The microdosimetric spectra were determined using the abridged microdosimetric distribution methodology (AMDM) and input into the MCF microdosimetric kinetic model (MKM) to determine spectral and RBE dependence on nozzle design. Monoenergetic carbon ion beams having a range in water of 3 and 27 cm were simulated. For the 27 cm beams, a simulated water-based range shifter was inserted before the phantom, reducing the range to 3 cm. Furthermore, a shallow spread-out Bragg peak (SOBP) (5-10 cm) and a deep SOBP (15-21 cm), were simulated for all nozzles and the resulting integrated dose profiles compared.

resultsFor all nozzle geometries, the range at 80% dose fall-off (R80) agreed within 0.1 mm. The lineal energy and the RBE agreed very well until the Bragg peak, after which some differences could be observed. For the SOBPs, the agreement was similar with an agreement in the biological dose before and at the SOBP within 0.7%. For the thick nozzle of Osaka HIMAK, small differences were observed, mostly in the fragmentation tail.

conclusionThe AMDM was successfully integrated into OpenGATE10 and used to compute the RBE with the MCF MKM. It was shown that the nozzle design itself had only a minor effect on the radiation quality and consequently the RBE. A small difference in RBE is observed mostly after the Bragg peak and SOBP in the fragmentation tail and depends on the nozzle water equivalent tissue (WET), when it is a change of more than 24 mm.

Indexed as

Heavy Ion RadiotherapyEquipment DesignHumansRadiometryRelative Biological EffectivenessCarbon ion radiation therapyMicrodosimetryMonte CarloNozzleRelative biological effectiveness