Evidence map›Paper›PMID 40345136›Full record

ArticleComputers in biology and medicine2025

A deployment safety case for AI-assisted prostate cancer diagnosis.

Yan Jia, Clare Verrill, Kieron White, Monica Dolton, Margaret Horton, Mufaddal Jafferji, Ibrahim Habli

Abstract read
In one paragraph

Article in Computers in biology and medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yan JiaDepartment of Computer Science, University of York, York, YO10 5GH, UK. Electronic address: yan.jia@york.ac.uk.
Clare VerrillDepartment of Cellular Pathology, Oxford University Hospitals NHS Foundation Trust, John Radcliffe Hospital, Headley Way, Oxford, OX3 9DU, UK; Nuffield Department of Surgical Sciences, University of Oxford, John Radcliffe Hospital, Headley Way, Oxford, OX3 9DU, UK; NIHR Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, John Radcliffe Hospital, Headley Way, Oxford, OX3 9DU, UK. Electronic address: Clare.Verrill@ouh.nhs.uk.
Kieron WhiteDepartment of Cellular Pathology, Oxford University Hospitals NHS Foundation Trust, John Radcliffe Hospital, Headley Way, Oxford, OX3 9DU, UK. Electronic address: Kieron.White@ouh.nhs.uk.
Monica DoltonNuffield Department of Surgical Sciences, University of Oxford, John Radcliffe Hospital, Headley Way, Oxford, OX3 9DU, UK. Electronic address: monica.dolton@nds.ox.ac.uk.
Margaret HortonPaige, 11 Times Sq, Fl 37, New York, NY 10036, USA. Electronic address: margaret.horton@paige.ai.
Mufaddal JafferjiPaige, 11 Times Sq, Fl 37, New York, NY 10036, USA. Electronic address: mufaddal.jafferji@paige.ai.
Ibrahim HabliDepartment of Computer Science, University of York, York, YO10 5GH, UK. Electronic address: Ibrahim.Habli@york.ac.uk.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Deep learning (DL) has the potential to deliver significant clinical benefits. In recent years, an increasing number of DL-based systems have been approved by the relevant regulators, e.g. FDA. Although obtaining regulatory approvals is a prerequisite to deploy such systems for real world use, it may not be sufficient. Regulatory approvals give confidence in the development process for such systems, but new hazardous events can arise depending on how the systems have been deployed in the intended clinical pathways or how they have been used with other systems in complex healthcare settings. These kinds of events can be difficult to predict during the development process. Indeed, most health systems and hospitals require self-verification before deploying a diagnostic medical device, which could be viewed as an additional safety measure. This shows that it is important to carry on assuring the safety of such systems in deployment. In this work, we address this urgent need based on the experience of a prospective study in UK hospitals as part of the ARTICULATE PRO project. In particular, the system considered in this work is developed by Paige for prostate cancer diagnosis, which has obtained FDA approval in the US and UKCA marks in the UK. The methodology presented in this work starts by mapping out the clinical workflow within which the system has been deployed, then carries out hazard and risk analysis based on the clinical workflow, and finally presents a deployment safety case, which provides a basis for deployment and continual monitoring of the safety of this system in use. In this work we systematically address the emergence of new hazardous events from the deployment and to present a way to continually assure the safety of a regulatorily approved system in use.

Indexed as

Deep LearningDiagnosis, Computer-AssistedProstatic NeoplasmsHumansMaleAI safetyArtificial intelligenceDeep learningHistopathologyProstate cancer diagnosisSafety case

Identifiers

PMID40345136
PMCPMC12131227

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.