Evidence map›Paper›PMID 40344194›Full record

ArticleMedical physics2025

Learned high resolution energy-integrating detector CT angiography: Harnessing the power of ultra-high-resolution photon counting detector CT.

Emily K Koons, Shaojie Chang, Andrew D Missert, Hao Gong, Jamison E Thorne, Safa Hoodeshenas, Prabhakar Shantha Rajiah, Cynthia H McCollough, Shuai Leng

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Emily K KoonsDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Shaojie ChangDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Andrew D MissertDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Hao GongDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Jamison E ThorneDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Safa HoodeshenasDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Prabhakar Shantha RajiahDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Shuai LengDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.

Funding

Comprehensive characterization of coronary atherosclerotic disease using photon-counting-detector dual-source CT and its impact on patient managementR01EB028590 · NIBIB · MAYO CLINIC ROCHESTER · PI LENG, SHUAI, MCCOLLOUGH, CYNTHIA H · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB028590NIH HHS R01 EB028590
6 · The paper itself

Abstract

backgroundCoronary computed tomography angiography (cCTA) is a widely used noninvasive diagnostic exam to assess patients for coronary artery disease (CAD). However, the spatial resolution of most CT scanners is limited due to the use of energy-integrating detectors (EIDs). PURPOSE: To develop a convolutional neural network (Improved LUMEN visualization through Artificial super-resoluTion imagEs (ILUMENATE)) informed by photon-counting-detector (PCD)-CT to improve EID-CT image resolution and determine its impact on cCTA. MATERIALS AND

methodsWith IRB approval, 30 patients undergoing clinically indicated cCTA were scanned with EID-CT (SOMATOM Force, Siemens Healthineers, Forchheim, Germany) and subsequently with ultra-high-resolution (UHR) PCD-CT (NAEOTOM Alpha, Siemens Healthineers) on the same day. ILUMENATE was trained on eight patient PCD-CT datasets (67,890 patch pairs with 90% for training (61,101), 10% reserved for validation (6,789)) and applied to 22 unseen EID-CT cases. Spatial resolution was evaluated using line profiles and percent diameter stenosis quantified with a severity score assigned. Two experienced radiologists, blinded to image type, selected preferred series and scored images for overall quality, sharpness, and noise comparing original EID-CT and ILUMENATE output.

resultsVisual assessment and line profiles showed substantial resolution improvement with ILUMENATE. Percent diameter stenosis was significantly reduced (mean ± standard deviation: 4.42% ± 4.82%) using ILUMENATE (p < 0.001) with nine lesions shifting down in severity score. Readers preferred ILUMENATE images in 22/22 cases and scored ILUMENATE superiorly for overall quality, sharpness, and noise (p < 0.05).

conclusionsILUMENATE enhanced image resolution, resulting in improved overall image quality, reduced calcium blooming artifacts, and improved lumen visibility in cCTA exams performed using EID-CT. This could potentially allow for improved accessibility to UHR image quality, allowing for more accurate assessment of CAD.

Indexed as

Computed Tomography AngiographyPhotonsSignal-To-Noise RatioAgedFemaleHumansImage Processing, Computer-AssistedMaleMiddle AgedNeural Networks, Computercoronary artery diseasecoronary artery stenosiscoronary CT angiographyphoton‐counting‐detector CTsuper resolution

Identifiers

PMID40344194
PMCPMC12259352

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.