A virtual imaging study of microcalcification detection performance in digital breast tomosynthesis: Patients versus 3D textured phantoms.

Katrien Houbrechts, Lesley Cockmartin, Nicholas Marshall, Liesbeth Vancoillie, Stoyko Marinov, Ruben Sanchez de la Rosa, Remy Klausz, Ann-Katherine Carton, Hilde Bosmans

Abstract readComparative Study
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. The Next Frontier in Quantitative Co-Clinical Imaging to Advance Functional Precision Oncology.Clinical cancer research : an official journal of the American Association for Cancer Research · 2026
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Katrien HoubrechtsMedical Physics and Quality Assessment, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium.
Lesley CockmartinDepartment of Radiology, UZ Leuven, Leuven, Belgium.
Nicholas MarshallMedical Physics and Quality Assessment, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium.
Liesbeth VancoillieMedical Physics and Quality Assessment, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium.
Stoyko MarinovMedical Physics and Quality Assessment, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium.
Ruben Sanchez de la RosaGE Healthcare, Buc, France.
Remy KlauszGE Healthcare, Buc, France.
Ann-Katherine CartonGE Healthcare, Buc, France.
Hilde BosmansMedical Physics and Quality Assessment, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium.

Funding

GE Healthcare
6 · The paper itself

Abstract

backgroundClinical studies to evaluate the performance of new imaging devices require the collection of patient data. Virtual methods present a potential alternative in which patient-simulating phantoms are used instead. PURPOSE: This work uses a virtual imaging technique to examine the extent to which human observer microcalcification detection performance in phantom backgrounds matches that in real patient backgrounds for digital breast tomosynthesis (DBT).

methodsThis work used the following DBT image datasets: (1) 142 real patient images and (2) 20 real images of the physical L1 phantom, both acquired on a GEHC Senographe Pristina system; (3) 217 simulated images of the Stochastic Solid Breast Texture (SSBT) phantom and (4) 217 simulated images of the digital L1 phantom, both created with the CatSim framework. The L1 phantom is a PMMA container filled with water and PMMA spheres of varying diameters. The SSBT phantom is a computational phantom composed of glandular and adipose tissue compartments. Signal-present images were generated by inserting simulated microcalcification clusters, containing individual calcifications with thicknesses and projected areas in the range of 165-180 µm, 195-210 µm and 225-240 µm, and 0.025-0.031 mm

resultsMean AUC for the patient images was 0.70 ± 0.04, while mean AUCs of 0.74 ± 0.04, 0.76 ± 0.03, and 0.76 ± 0.07 were found for the SSBT, physical L1 and digital L1 phantoms, respectively. The AUC for the physical and digital L1 phantoms was equivalent (p = 0.03), as well as for the patients and SSBT backgrounds (p = 0.002). The physical and digital L1 images did not have equivalent detection performance compared to patient images (p = 0.06 and p = 0.9, respectively). In patient backgrounds, the correctly detected fraction of microcalcifications clusters fell from 0.53 for the lowest density (VBD < 4.5%) to 0.40 for the highest density (VBD ≥ 15.5%). Microcalcification detection fractions were 0.52, 0.55, and 0.55 for the SSBT, physical L1 and digital L1 backgrounds, respectively.

conclusionsDetection levels were equivalent between the physical and digital versions of the L1 phantom. Detection in L1 and patient backgrounds was not equivalent, however, differences in detection performance were small, confirming the potential value of this phantom. The digital SSBT phantom was found to be equivalent to patient backgrounds for DBT studies of microcalcification cluster detection performance, for the DBT system and reconstruction algorithm used in this study.

Indexed as

BreastBreast NeoplasmsCalcinosisImaging, Three-DimensionalMammographyPhantoms, ImagingFemaleHumansdetectiondigital breast tomosynthesisdigital phantomsvirtual imaging trial