Exploring bias in spectral CT material decomposition: a simulation-based approach.

Milan Smulders, Dufan Wu, Rajiv Gupta

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Theoretical Prediction of Bias in Model-Based Material Decomposition.Proceedings of SPIE--the International Society for Optical Engineering · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Milan SmuldersUniversity of Twente (The Netherlands).
Dufan WuMassachusetts General Hospital (United States).
Rajiv GuptaMassachusetts General Hospital (United States).

Funding

Optimizing Mobile Photon-Counting CT Image Quality via Deep Learning for Neuro Intensive Care UnitR01EB035394 · NIBIB · OHIO STATE UNIVERSITY · PI Rajiv Gupta, Dufan Wu · 2024 to 2026
$1.3M
Dual Energy CT-enabled Asymptomatic Pulmonary Embolism Detection on Non-contrast CTR21EB031939 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI WU, DUFAN · 2021 to 2021
$449k
NIBIB NIH HHS R01 EB035394NIBIB NIH HHS R21 EB031939
6 · The paper itself

Abstract

Introduction -: Computed tomography (CT) imaging has seen significant advancements with the introduction of spectral CT, which improves material differentiation by acquiring images at multiple energy levels. Photon-counting CT (PCCT) is an emerging technique to implement spectral CT with photon counting detectors that may discriminate detected photon energies to different energy bins. Material differentiation is achieved by decomposing the acquired data into two-material models such as brain/bone or brain/iodine. However, such decomposition is susceptible to bias due to inaccurate physical modeling. In this study, we aim to study the relationship between the material decomposition bias and the energy thresholds used in PCCT, under ideal, noiseless models. Methods -: A projection-based material decomposition model was used to directly decompose projection data. Bias simulation was performed using a Shepp-Logan phantom with brain/bone and brain/iodine as basis materials. X-ray spectra were generated using a fixed 10 keV threshold and a varying threshold sampled from 20 to 90 keV, with extra sampling points around iodine's k-edge. Virtual monoenergetic images (VMIs) at 60 keV and 140 keV were analyzed to evaluate bias for each material and material pair. Results -: Lower energy thresholds (<40 keV) introduced a larger bias in material decomposition, with peaks observed between 30 and 40 keV, particularly around the k-edge of iodine. The bias generally decreased with increasing thresholds above 50 keV, especially for non-basis materials. This trend was consistent across brain/bone and brain/iodine bases and for both 60 and 140 keV VMIs. Conclusion -: Energy thresholds significantly affect the accuracy of projection-based material decomposition in PCCT. Greater differences between thresholds lead to reduced decomposition bias. Future research should incorporate non-ideal detector responses and noise, as well as explore image-domain decomposition and real phantom studies with possible translation to improve patient care.

Indexed as

biasenergy thresholdsmaterial decompositionphoton counting CTSpectral CT

Identifiers

PMID40343264
PMCPMC12060251