Evidence map›Paper›PMID 40341378›Full record

ArticleMicrosystems & nanoengineering2025

Synchronous detection of dual signals based on constant-drive technique of weakly coupled resonators.

Han Li, Zhao Zhang, PeiYuan Zhu, GuoHua Zhang, Yongcun Hao, Honglong Chang

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Han LiMinistry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China.
Zhao ZhangMinistry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China.
PeiYuan ZhuMinistry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China.
GuoHua ZhangMinistry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China.
Yongcun HaoMinistry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China. haoyongcun@nwpu.edu.cn.ORCID http://orcid.org/0000-0003-4853-5808
Honglong ChangMinistry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China. changhl@nwpu.edu.cn.ORCID http://orcid.org/0000-0003-0400-3658

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The demand for highly sensitive and accurate sensors has grown significantly, particularly in the field of Micro-Electro-Mechanical Systems technology. Mode-localized sensors based on weakly coupled resonators have garnered attention for their high sensitivity through amplitude ratio outputs. However, when measuring multiple signals by weakly coupled resonators, different signals can interfere with each other, causing high cross-sensitivity. This cross-sensitivity greatly complicates signal separation and makes accurate measurement extremely difficult, impacting system performance. To address this issue, the study proposes an innovative constant-drive technique of weakly coupled resonators. This technique significantly reduces crosstalk between signals while maintaining high sensitivity of amplitude ratio output. The method is theoretically validated by analyzing amplitude ratios under signal perturbations in non-damped conditions, demonstrating perfect elimination of cross-interference. Finite element analysis under damping conditions further validated the constant-drive technique, showing a cross-sensitivity of 0.054%, nearly three orders of magnitude lower than that of mode-localized sensors. Experimental validation confirmed the effectiveness of the proposed technique, with the cross-sensitivity of the mode-localized method measured at 26.3% and 28.7%, respectively, while the constant-frequency drive achieved significantly lower values of 3.1% and 1.1%. This demonstrates a successful reduction in cross-sensitivity by an order of magnitude, meeting the performance requirements for typical MEMS biaxial sensor applications. This method is highly significant for mode-localized sensors, offering potential for developing multi-signal measurement devices like multi-axis accelerometers, force sensor, electric field sensor and mass sensor.

Identifiers

PMID40341378
PMCPMC12062247

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.