ArticleMicrosystems & nanoengineering2025
Synchronous detection of dual signals based on constant-drive technique of weakly coupled resonators.
Article in Microsystems & nanoengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Dispersive coupling and dual-mode sensing of a micromechanical resonator.Microsystems & nanoengineering · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The demand for highly sensitive and accurate sensors has grown significantly, particularly in the field of Micro-Electro-Mechanical Systems technology. Mode-localized sensors based on weakly coupled resonators have garnered attention for their high sensitivity through amplitude ratio outputs. However, when measuring multiple signals by weakly coupled resonators, different signals can interfere with each other, causing high cross-sensitivity. This cross-sensitivity greatly complicates signal separation and makes accurate measurement extremely difficult, impacting system performance. To address this issue, the study proposes an innovative constant-drive technique of weakly coupled resonators. This technique significantly reduces crosstalk between signals while maintaining high sensitivity of amplitude ratio output. The method is theoretically validated by analyzing amplitude ratios under signal perturbations in non-damped conditions, demonstrating perfect elimination of cross-interference. Finite element analysis under damping conditions further validated the constant-drive technique, showing a cross-sensitivity of 0.054%, nearly three orders of magnitude lower than that of mode-localized sensors. Experimental validation confirmed the effectiveness of the proposed technique, with the cross-sensitivity of the mode-localized method measured at 26.3% and 28.7%, respectively, while the constant-frequency drive achieved significantly lower values of 3.1% and 1.1%. This demonstrates a successful reduction in cross-sensitivity by an order of magnitude, meeting the performance requirements for typical MEMS biaxial sensor applications. This method is highly significant for mode-localized sensors, offering potential for developing multi-signal measurement devices like multi-axis accelerometers, force sensor, electric field sensor and mass sensor.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.