Evidence map›Paper›PMID 40337744›Full record

ReviewInterventional cardiology (London, England)2015

BiOSS® Clinical Programme - State of the Art - BiOSS LIM® Stent - The Novel Option for Coronary Bifurcation Treatment.

Jacek Bil, Robert J Gil, Dobrin Vassilev

Abstract readReview
In one paragraph

Review in Interventional cardiology (London, England), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jacek BilDepartment of Invasive Cardiology, Central Clinical Hospital of the Ministry of Interior Warsaw, Poland.
Robert J GilDepartment of Invasive Cardiology, Central Clinical Hospital of the Ministry of Interior Warsaw, Poland.
Dobrin VassilevAlexandrovska University Hospital Sofia, Bulgaria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The BiOSS LIM® (Bifurcation Optimization Stent System, Balton, Warsaw, Poland) stent is a coronary, dedicated bifurcation, balloonexpandable stent made of 316 L stainless steel with a strut thickness of 120 μm. It is covered with a mixture of a biodegradable polymer and the antiproliferative substance: sirolimus. The stent consists of two parts (the proximal with a larger diameter in relation to the distal one) connected with two struts (average 1.5 mm length) at the middle zone. The stent is crimped on a bottle-shaped semi-compliant balloon (Bottle®, Balton, Warsaw, Poland). Our intravascular ultrasound (IVUS) study revealed that the construction of the BiOSS® stent allows easy access to the side branch, similar to the classic stent lumen enlargement with less injury to the area adjacent to the most sensitive part of the bifurcation. The BiOSS LIM® stent has already been thoroughly investigated: initially in the First-In-Man registry with 60 patients, then in the registry in a high-risk population with distal left main stenosis and finally in a randomised clinical trial POLBOS II. The long-term clinical results were satisfactory and closely related to the high-risk profile of the treated population. Our data demonstrated that the simple and fast bifurcation treatment with a single dedicated bifurcation sirolimus-eluting stent (BiOSS LIM®) is feasible and highly successful.

Indexed as

BiOSS LIM®Dedicated bifurcation stentsirolimus-eluting stent

Identifiers

PMID40337744
PMCPMC12054335

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.