Evidence map›Paper›PMID 40337621›Full record

ArticleResearch and practice in thrombosis and haemostasis2025

Comparison of 2 thromboelastography methods using patient and control samples.

Robert Frick, Brittany Washburn, Dennis Plocher, Jonathan K Zoller, Jason Gillihan, Michael Dombrowski, Charles Eby, Christopher W Farnsworth

Abstract read
In one paragraph

Article in Research and practice in thrombosis and haemostasis, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Robert FrickDepartment of Pathology & Immunology, Washington University School of Medicine, St. Louis, Missouri, USA.
Brittany WashburnDepartment of Laboratories, Barnes Jewish Hospital, St. Louis, Missouri, USA.
Dennis PlocherDepartment of Laboratories, Barnes Jewish Hospital, St. Louis, Missouri, USA.
Jonathan K ZollerDepartment of Anesthesiology, Washington University in St. Louis, St. Louis, Missouri, USA.
Jason GillihanDepartment of Anesthesiology, Washington University in St. Louis, St. Louis, Missouri, USA.
Michael DombrowskiDepartment of Anesthesiology, Washington University in St. Louis, St. Louis, Missouri, USA.
Charles EbyDepartment of Pathology & Immunology, Washington University School of Medicine, St. Louis, Missouri, USA.
Christopher W FarnsworthDepartment of Pathology & Immunology, Washington University School of Medicine, St. Louis, Missouri, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Viscoelastic testing at point-of-care is associated with reduced blood loss and blood product transfusions. The ROTEM (Werfen) sigma is a cartridge-based system that may facilitate point-of-care use, but limited studies exist comparing the sigma with the predicated ROTEM delta. Objectives: We compared the performance of the ROTEM delta with that of the sigma. Methods: Citrated blood was collected from 20 healthy donors and patients during liver transplants ( Results: The coefficient of variation was <10% for all assays/parameters except for the thromboelastometry with extrinsic activation (EXTEM) clotting time (10.3%) and EXTEM amplitude (A)5 (10.2%). Reference intervals for the delta and sigma were comparable to manufacturer claims. The Pearson r comparing the delta and sigma exceeded .85 for all parameters/assays except for thromboelastometry with cytochalasin D-mediated platelet inhibition (FIBTEM) A10 (.77; 95% CI, .66-.86), FIBTEM A20 (.78; 95% CI, .65-.87), and thromboelastometry with heparinase clotting time (.77; 95% CI, .61-.87). No difference was observed in extrapolated thresholds from the delta-guided algorithm. However, extrapolated sigma A5 parameters for EXTEM were 5 mm lower, and for FIBTEM were 1 mm lower than delta A10 parameters. Conclusion: The ROTEM delta and sigma devices had comparable performance. A negative bias was observed in the FIBTEM assay with lower extrapolated clinical decision points for a delta-guided treatment algorithm for the FIBTEM and EXTEM A5.

Indexed as

blood product utilizationcoagulationmethod comparisonthromboelastometrytransfusion

Identifiers

PMID40337621
PMCPMC12056965

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.