Evidence map›Paper›PMID 40336686›Full record

ArticleCanadian journal of kidney health and disease2025

Technical and Institutional Factors Affecting Specimen Adequacy and Complications in Ultrasound-guided Kidney Biopsy: A Retrospective Cohort Study.

Sydney Murray, Chance Dumaine, Chris Wall, Tamalina Banerjee, James Barton, Michael Moser

Abstract read
In one paragraph

Article in Canadian journal of kidney health and disease, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Performing a percutaneous kidney biopsy.World journal of nephrology · 2026
    Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sydney MurrayCollege of Medicine, University of Saskatchewan, Saskatoon, Canada.
Chance DumaineDepartment of Medicine, University of Saskatchewan, Saskatoon, Canada.ORCID https://orcid.org/0000-0001-8273-0717
Chris WallDepartment of Radiology, Saskatoon Health Region, SK, Canada.
Tamalina BanerjeeDepartment of Pathology and Laboratory Medicine, Saskatoon Health Region, SK, Canada.
James BartonDepartment of Medicine, University of Saskatchewan, Saskatoon, Canada.
Michael MoserDepartment of Surgery, University of Saskatchewan, Saskatoon, Canada.ORCID https://orcid.org/0000-0003-0735-199X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Percutaneous ultrasound-guided kidney biopsy is a critical diagnostic tool with a higher rate of complications than most other biopsies. Our prior research identified technical factors that might improve outcomes. Objective: The objective was to measure the impact of these technical and institutional interventions on specimen adequacy and complication rates in kidney biopsies. Design: This is a retrospective cohort study comparing outcomes before and after intervention implementation. Setting: Two hospitals within a single health region in Saskatchewan serving a population of approximately 1 million. Patients: All adult percutaneous ultrasound-guided kidney biopsies performed on adult patients between 2012 to 2016 (n = 242, pre-implementation) and 2017 to 2021 (n = 338, post-implementation). Both native and transplant biopsies were included, while patients under 18, open biopsies, and biopsies of kidney masses were excluded. Measurements: Primary outcomes included specimen adequacy and biopsy complications (hematoma, hemoglobin drop, infection, and arteriovenous fistula formation). Methods: Technical recommendations included introducing the biopsy needle at a 60° angle, targeting a pole, and avoiding the vascular medulla. Institutional recommendations included microscopic screening for all biopsies, limiting the number of radiologists performing procedures, using a checklist, and restricting computed tomography (CT)-guided biopsies to exceptional cases. Multivariate regression analysis assessed biopsy outcomes before and after the recommendations, controlling for known confounders while at the same time refining factors associated with fewer complications and greater diagnostic yield. Results: The rate of non-diagnostic specimens decreased from 10.3% to 4.4% ( Limitations: Retrospective design and novelty bias may be a cause of bias in this study. Because the institutional recommendations were followed for all biopsies, it was not possible to distinguish which recommendation was most associated with the improvements. Because our study was done in a single health region, it is not clear if they are generalizable to other programs. Conclusions: The technical and institutional interventions implemented significantly improved specimen adequacy and reduced complication rates in ultrasound-guided kidney biopsies. We have added to these recommendations in that we have refined the requirement for angling the biopsy needle for ease of use and suggest limiting the number of passes to 2 or 3 whenever possible.

Indexed as

complicationskidney biopsymultivariate analysisspecimen adequacytechnical factorsultrasound

Identifiers

PMID40336686
PMCPMC12056320

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.