Evidence map›Paper›PMID 40332893›Full record

ArticleTranslational vision science & technology2025

Comparing the Efficiency of Fluid Infusion Systems for Pars Plana Vitrectomy.

Tommaso Rossi, Giorgio Querzoli, Giov Battista Angelini, Veronica Santoro, Camilla Pellizzaro, David H Steel, Mariacristina Parravano, Mario R Romano

Abstract readComparative Study
In one paragraph

Article in Translational vision science & technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tommaso RossiIRCCS, Fondazione Bietti ONLUS, Rome, Italy.
Giorgio QuerzoliDICAAR Faculty of Engineering, University of Cagliari, Caligari, Italy.
Giov Battista AngeliniBeaver Visitec Medical, Rome, Italy.
Veronica SantoroIRCCS, Fondazione Bietti ONLUS, Rome, Italy.
Camilla PellizzaroIRCCS, Fondazione Bietti ONLUS, Rome, Italy.
David H SteelBiosciences Institute, Newcastle University, Newcastle Upon Tyne, UK.
Mariacristina ParravanoIRCCS, Fondazione Bietti ONLUS, Rome, Italy.
Mario R RomanoDepartment of Biomedical Science, Humanitas University, Milan, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To compare the efficiency of infusion sets including distal tubing, infusion, and trocar cannulas (23G, 25G, 27G) of leading brands (Alcon, Bausch & Lomb, BVI, DORC, Optikon) in minimizing the intraocular pressure drop on aspiration. The study reports the pressure drop along infusion as a function of the flow rate and correlates performance to design. Methods: We measured the pressure drop of the distal silicone tubing, infusion cannula and trocar cannula, connected to a model eye and the corresponding flow rate. The piezometric height of the balanced salt solution (BSS) reservoir open to atmospheric pressure ranged from 10 to 120 cm above outlet. All infusion set components were measured in length and inner lumen diameter. Results: Pressure drop as a function of flow rate varied significantly: BVI and DORC proved more efficient at all gauges. Pressure drop at 10 mL/min flowrate varied between 9-16 mm Hg for 23G, 11-25 mm Hg for 25G, and 16-50 mm Hg for 27G. The tubing friction and kinetic energy loss, respectively responsible for the linear and quadratic component of the head-loss to flow rate parabolic function, also differed significantly. Conclusions: Pressure drop secondary to flow rate varied by a factor of two among manufacturers. Excessive pressure drop during aspiration may lead to dangerous hypotony or force the surgeon to set anomalously high pressures at rest to avoid it. The present study gives useful insights to help improve infusion system performance. Translational Relevance: A thorough understanding of head loss mechanisms along infusion sets allows the design of more efficient and safer infusion sets.

Indexed as

VitrectomyCannulaEquipment DesignHumansInfusion PumpsIntraocular Pressure

Identifiers

PMID40332893
PMCPMC12061064

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.