ArticleJournal of mass spectrometry and advances in the clinical lab2025
Development of an isotope dilution gas chromatography - mass spectrometry candidate reference measurement procedure for glucose in human serum.
Article in Journal of mass spectrometry and advances in the clinical lab, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- From population science to the clinic? Limits of epigenetic clocks as personal biomarkers.Epigenomics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Diabetes is the seventh leading cause of death in the United States, impacting over 37 million people. Accurate glucose measurements are critical for effective diabetes management. A reliable candidate reference measurement procedure (cRMP) for assessing the analytical performance of glucose tests performed in patient care is essential for ensuring measurement accuracy. Methods: We have developed a gas chromatography-mass spectrometry (GC-MS)-based cRMP for glucose in human serum. In this procedure, glucose is measured as the aldononitrile acetate derivative and quantitated using a Results: Analytical selectivity was achieved through chromatographic separation and monitoring the quantitation ion/confirmation ion ratios in samples. With bias ranging from -0.79 % to 0.67 % for eight levels of serum-based certified reference materials from the National Institute of Standards and Technology (NIST) and Laboratoire national de métrologie et d'essais (LNE) and total CVs of 1.11 %, 0.68 % and 0.74 % at the low, medium, and high glucose concentration levels, respectively, the cRMP provided excellent accuracy and precision. The calibration curve was linear throughout the 13.51-378.21 mg/dL [0.75-21 mmol/L] measurement range (R Conclusion: The described GC-MS method, with metrological traceability to the International System of Units (SI), provides highly accurate and precise measurements of glucose in human serum.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.