Evidence map›Paper›PMID 40330937›Full record

ArticleAME case reports2025

Difficult insertion of a transesophageal echocardiography probe for cardiac surgery not only before but also immediately after thyroid goiter resection in a patient with chronic esophageal compression by the goiter: a case report.

Masataka Fukuda, Tsukasa Kochiyama, Kota Aono, Shuhei Yonemoto, Megumi Hayashi, Masakazu Hayashida, Izumi Kawagoe

Abstract readCase Reports
In one paragraph

Article in AME case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Masataka FukudaDepartment of Anesthesiology and Pain Medicine, Juntendo University Faculty of Medicine and Graduate School of Medicine, Tokyo, Japan.ORCID https://orcid.org/0000-0002-8283-5233
Tsukasa KochiyamaDepartment of Anesthesiology and Pain Medicine, Juntendo University Faculty of Medicine and Graduate School of Medicine, Tokyo, Japan.
Kota AonoDepartment of Anesthesiology and Pain Medicine, Juntendo University Faculty of Medicine and Graduate School of Medicine, Tokyo, Japan.
Shuhei YonemotoDepartment of Anesthesiology and Pain Medicine, Juntendo University Faculty of Medicine and Graduate School of Medicine, Tokyo, Japan.
Megumi HayashiDepartment of Anesthesiology and Pain Medicine, Juntendo University Faculty of Medicine and Graduate School of Medicine, Tokyo, Japan.
Masakazu HayashidaDepartment of Anesthesiology and Pain Medicine, Juntendo University Faculty of Medicine and Graduate School of Medicine, Tokyo, Japan.
Izumi KawagoeDepartment of Anesthesiology and Pain Medicine, Juntendo University Faculty of Medicine and Graduate School of Medicine, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transesophageal echocardiography (TEE) is an essential tool during minimally invasive cardiac surgery (MICS), although inserting a TEE probe is sometimes challenging. We experienced difficult placement of an adult TEE probe for cardiac surgery due to chronic compression of the esophagus by thyroid goiter. The aim of this case report is to highlight the challenges of TEE probe insertion due to chronic esophageal compression caused by a thyroid goiter and to discuss considerations for simultaneous thyroid tumor resection and mitral valvuloplasty (MVP). Case Description: A 78-year-old man (170 cm, 68 kg) with severe mitral regurgitation (MR) was scheduled for simultaneous thyroid surgery and MVP, since preoperatively, experienced cardiologists had failed to place an adult TEE probe for preoperative TEE examinations, and they had had to use a pediatric TEE probe with poor image quality. First, otolaryngologists completely resected the left thyroid lobe including goiter. However, even after tumor resection, experienced anesthesiologists could not advance the adult TEE probe beyond the pharynx due to strong resistance, even using video laryngoscopy to visualize the esophageal inlet. Again, they had to use a pediatric probe for intraoperative evaluation. Conclusions: Such previously unreported experiences suggested that esophageal stenosis due to chronic compression by goiter would not improve completely at least immediately after tumor resection. When usual TEE probe placement is difficult, alternative methods for assessing the mitral valve (MV) should be considered.

Indexed as

case reportMinimally invasive cardiac surgery (MICS)mitral valvuloplasty (MVP)thyroid tumortransesophageal echocardiography (TEE)

Identifiers

PMID40330937
PMCPMC12053728

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.