Evidence map›Paper›PMID 40329742›Full record

ArticleOrthopaedic surgery2025

H-Shaped Anatomical Titanium Plate: Biomechanical Validation and Clinical Application in the Treatment of Complex Posterior Wall/Column Acetabular Fractures.

Qiaoli Zhang, Liang Jin, Xiaorui Hao, Weijie Zheng, Fei Zhou, Shuxin Zhang, Tianfeng Li, Xiaohui Xiong, Yihan He, Xiaojie Chen and 1 more

Abstract readValidation Study
In one paragraph

Article in Orthopaedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Technical note: novel utilization of an H-plate for the treatment of posterior wall components of acetabular fractures.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Qiaoli ZhangDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.ORCID https://orcid.org/0009-0000-7530-0073
Liang JinDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.ORCID https://orcid.org/0009-0001-6374-3755
Xiaorui HaoDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.ORCID https://orcid.org/0009-0006-4921-3199
Weijie ZhengDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.ORCID https://orcid.org/0009-0002-1788-3607
Fei ZhouDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.ORCID https://orcid.org/0000-0002-9795-5676
Shuxin ZhangDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.ORCID https://orcid.org/0009-0005-7855-4526
Tianfeng LiDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.ORCID https://orcid.org/0009-0001-6001-2252
Xiaohui XiongDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.ORCID https://orcid.org/0009-0007-8548-8365
Yihan HeDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.ORCID https://orcid.org/0009-0007-3049-4418
Xiaojie ChenDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.
Jiexin HuangDepartment of Orthopedic Surgery, Nanping First Hospital Affiliated to Fujian Medical University, Nanping, China.ORCID https://orcid.org/0009-0009-3356-6418

Funding

Fujian Provincial Natural Science Foundation of China 2022J011487Nanping City Joint Fund Project for Scientific and Technological Innovation in the Medical and Health Field, China N2024LH010
6 · The paper itself

Abstract

objectiveApproximately 80% of acetabular fractures involve the posterior wall and posterior column, which are complex and challenging to treat. The H-shaped anatomical titanium plate (HTP) facilitates anatomical reduction, minimizes complications, and enhances safety, efficacy, and speed. This study aims to conduct biomechanical testing and clinical evaluation of HTP to assess its stability and efficacy in treating these fractures.

methodsIn the biomechanical research, posterior column with posterior wall fractures was created on nine acetabular models procured from Sawbones, USA and were allocated to three fixation groups: (1) a single reconstruction plate combined with a single cortical screw (PCS), (2) double parallel reconstruction plates (2P), (3) HTP. Following anatomic reduction, cyclic loading and destructive experiments were conducted to assess the efficacy of different fixation devices under various loads for the posterior wall and column, as well as their peak load and structural stiffness. Additionally, we retrospectively analyzed the clinical data of 53 patients (46 males, 7 females; mean follow-up 24.6 ± 3.2 months) with the HTP at our hospital from April 2017 to January 2023. Clinical outcomes mainly included changes in postoperative pain, reduction quality (Matta criteria), hip function (Merle d'Aubigné Postel/Harris scores), and the incidence of complications.

resultsBiomechanical results showed that in cyclic loading tests, the relative displacement of the posterior wall and the posterior column fixed with the HTP was smallest, with statistically significant differences (p < 0.05). In the destructive experiment, compared to the 2P group (2062.89 ± 375.45 N, 412.16 ± 25.87 N/mm) and the PCS group (1477.89 ± 161.57 N, 204.21 ± 34.94 N/mm), the HTP group (3342.67 ± 354.15 N, 652.52 ± 24.25 N/mm) demonstrated superior peak load and structural stiffness, with statistically significant differences (p < 0.05). Clinically, Postoperative Visual Analogue Scale scores significantly decreased, indicating effective pain management. 84.91% achieved anatomic reduction, with 92.45% and 90.56% good/excellent functional outcomes (Merle d'Aubigné Postel and Harris scores, respectively). The incidence of various complications was low, with no cases of implant failure observed.

conclusionsThe HTP demonstrates robust stability in biomechanical experiments, offering distinct advantages for clinical applications and widespread adoption. In the treatment of the posterior column/posterior wall fractures, the integrated fixation of HTP aligns with the physiological anatomy of the acetabulum and has the advantages of simple operation, short operation time, strong stability, minimal risk of vascular and nerve injury, and fewer complications.

Indexed as

AcetabulumBone PlatesFracture Fixation, InternalFractures, BoneAdultBiomechanical PhenomenaFemaleHumansMaleMiddle AgedRetrospective StudiesTitaniumTitaniumacetabular fracturesbiomechanicsH‐shaped anatomical titanium plateposterior column fractureposterior wall fracture