Evidence map›Paper›PMID 40327043›Full record

ArticleACS nano2025

Reproducible Transpalpebral Intraocular Pressure Sensing Enabled by Low-Energy-Barrier Ion Pumping.

Xueyang Ren, Xuefei Zhu, Xiaodong Shao, Wen Yang, Yanmei Meng, Shiyu Chen, Yannan Wang, Jianqing Li, Qin Jiang, Benhui Hu

Abstract read
In one paragraph

Article in ACS nano, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Xueyang RenSchool of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China.ORCID 0000-0002-7629-9948
Xuefei ZhuThe Affiliated Eye Hospital, Nanjing Medical University, Nanjing 210029, China.
Xiaodong ShaoThe Affiliated Eye Hospital, Nanjing Medical University, Nanjing 210029, China.
Wen YangThe Affiliated Eye Hospital, Nanjing Medical University, Nanjing 210029, China.
Yanmei MengThe Affiliated Eye Hospital, Nanjing Medical University, Nanjing 210029, China.
Shiyu ChenSchool of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China.
Yannan WangSchool of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China.
Jianqing LiSchool of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China.
Qin JiangThe Affiliated Eye Hospital, Nanjing Medical University, Nanjing 210029, China.
Benhui HuSchool of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China.ORCID 0000-0002-7404-6525

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Elevated intraocular pressure (IOP) is a major risk factor for blindness in glaucoma patients, highlighting the critical need for continuous IOP monitoring. While traditional transpalpebral tonometers (TTs) circumvent corneal contact by adopting Goldmann applanation principles through impulsive corneal flattening forces, their measurement accuracy is inherently compromised by eyelid-induced cushion effects. In contrast, parallel-plate capacitive sensors employ constant compressive loading upon the eyelid, achieving palpebral compaction to mitigate the cushion effects. More recently, ion-pump-based capacitive sensors have emerged as promising alternatives, particularly due to their enhanced sensitivity. Nevertheless, these sensors exhibit sharp sensitivity deterioration at extended measurement ranges (0-10 kPa). This operational constraint originates from the strong hydrogen bond energies (between confining matrices and ions) and rigid block copolymer matrices' steric hindrance. To address these limitations, we developed a transpalpebral tonometer featuring low-energy-barrier ion pumps, incorporating (3-aminopropyl)triethoxysilane (APTES)-silanized liquid metal nanoparticles (LM NPs) as confining matrices and an ionic liquid as an ion donor. The low-energy barrier arises from (1) weaker hydrogen bonds between the N-H of APTES and the F of the ionic liquid and (2) reduced crystallinity in the elastomeric matrices induced by LM NPs. Our sensor achieves a sensitivity of 24.88 kPa

Indexed as

Intraocular PressureTonometry, OcularAnimalsGlaucomaHumansMetal NanoparticlesSilanesSilanescapacitive sensorsintraocular pressure monitoringion pumpsliquid metal nanoparticlestranspalpebral tonometers

Identifiers

PMID40327043
PMCPMC12097244

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.