Evidence map›Paper›PMID 40325470›Full record

Trial reportBMC oral health2025

Digital versus conventional techniques for construction of mandibular implant retained overdenture.

Abd Elsalam Awad Ali, Ahmed Habib, Mohamed Shady

Registry-linked trialAbstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06139003 (Evaluation of Digital Versus Conventional Techniques for Construction of Mandibular Implant Retained Overdenture), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06139003 nacompletednot on this map

Evaluation of Digital Versus Conventional Techniques for Construction of Mandibular Implant Retained Overdenture

TypeinterventionalSponsorMansoura UniversityRan2022 to 2023Enrolled20ConditionsOcclusal Wear of TeethArms3d Printed implant, Conventionally constructed implant
3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Abd Elsalam Awad AliProsthodontics Department, Faculty of Dentistry, Mansoura University, El Gomhoria street, Mansoura, 35516, Egypt.
Ahmed HabibProsthodontics Department, Faculty of Dentistry, Mansoura University, El Gomhoria street, Mansoura, 35516, Egypt.
Mohamed ShadyProsthodontics Department, Faculty of Dentistry, Mansoura University, El Gomhoria street, Mansoura, 35516, Egypt. Mohamedshady@mans.edu.eg.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to evaluate two different construction techniques (conventional and 3D-printed techniques) for two implant-retained complete mandibular overdentures regarding mechanical wear of the occlusal surface using 3D digital analysis and occlusion force distribution using the digital occlusal analysis system (Occlusense).

methodsTwenty patients were selected for this study from the prosthetic department, Faculty of Dentistry, Mansoura University. Each patient received two implants in the mandibular canine areas with locator attachments to retain the overdentures. According to the overdenture construction technique, all patients were randomly divided into two equal groups: the conventional heat polymerized overdenture group and the 3D-printed overdenture group. The mandibular overdentures were compared and evaluated immediately and after 12 months of insertion regarding mechanical wear of the occlusal surface using 3D digital analysis and occlusal force distribution using a digital occlusal analysis system (Occlusense).

results3d printed group showed significantly higher occlusal surface wear than conventional group after twelve months (T12) with a p value ≤ 0.05. 3d printed group showed significantly more occlusal force distribution than conventional group with a p value ≤ 0.05. Also, there was a significant difference in occlusal force distribution with advance of time for each group, with a p value ≤ 0.05 level of significance.

conclusionWithin the limitations of this study, it was shown that implant overdentures constructed by 3D-printing techniques offer a promising results in distribution of occlusal forces for achieving occlusal equilibration. However, in term of wear resistance more developments need to be done to improve material properties.

trial registrationThe study was approved by the local ethical committee of the Faculty of Dentistry, Mansoura University (No. A02060922) (6/9/2022) and retrospectively registered at ClinicalTrials.gov (ClinicalTrials.gov Identifier NCT06139003) (16/11/2023).

Indexed as

Dental Prosthesis, Implant-SupportedDenture, Complete, LowerDenture DesignDenture, OverlayPrinting, Three-DimensionalAdultBite ForceFemaleHumansMaleMandibleMiddle Aged3D-Printed overdentureCAD-CAMImplantLocator attachmentOcclusal force distributionOcclusal wearOcclusenseSuperimposition

Identifiers

PMID40325470
PMCPMC12054292

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials