Evidence map›Paper›PMID 40325279›Full record

ArticleClinical oral investigations2025

Torsional resistance of additively, subtractively, and conventionally manufactured occlusal devices.

Tina Maleki, Andrea Coldea, John Meinen, Marcel Reymus, Daniel Edelhoff, Bogna Stawarczyk

Abstract read
In one paragraph

Article in Clinical oral investigations, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tina MalekiDepartment of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany. Tina.Maleki@med.uni-muenchen.de.
Andrea ColdeaDepartment of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
John MeinenDepartment of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
Marcel ReymusDepartment of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
Daniel EdelhoffDepartment of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.
Bogna StawarczykDepartment of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestrasse 70, 80336, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo investigate the torque load (TL) and angular rotation (AR) of additively, subtractively and conventionally manufactured occlusal devices. MATERIALS AND

methodsSpecimens (N = 120) were fabricated from four additive manufacturing resins (GR-10 guide, ProArt Print Splint clear, V-Print Splint, V-Print Splint comfort), five subtractively (BioniCut, EldyPlus, ProArt CAD Splint clear, Temp Premium Flexible, Thermeo) and one conventionally manufactured (Pro Base Cold) materials. The TL and AR were tested initially (24 h, 37 °C, H

resultsInitially, the mean TL values ranged from 63.7 to 104 Ncm for additively, 39.2 to 265 Ncm for subtractively, and 204 Ncm for conventionally manufactured materials. The initial mean AR values were 41.7 to 143 deg for additively, 38.4 to 138 deg for subtractively, and 29.3 deg for conventionally manufactured materials. After thermal cycling, the mean TL values ranged from 45.7 to 88.1 Ncm for additively, 31.2 to 246 Ncm for subtractively, and 138 Ncm for conventionally manufactured materials. The mean AR values after aging ranged from 19.9 to 124 deg for additively, 48.1 to 131 deg for subtractively, and 19.5 deg for conventionally manufactured materials.

conclusionsThe torsional resistance of additively, subtractively, and conventionally manufactured materials for occlusal devices varies and is affected by aging processes. CLINICAL RELEVANCE: Material selection for occlusal devices should be guided by the clinical needs of the patients.

Indexed as

Dental MaterialsOcclusal SplintsOrthodontic Appliance DesignTorsion, MechanicalComputer-Aided DesignDental Stress AnalysisHumansMaterials TestingRotationTorqueDental Materials3D-printingAngular rotationOcclusal devicesTorque loadTorsion

Identifiers

PMID40325279
PMCPMC12053082

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.