Evidence map›Paper›PMID 40325096›Full record

ArticleScientific reports2025

A new design to improve time resolution in a time of flight brain PET using dual layer offset scintillator crystals.

Amir Beheshti, Alireza Karimian, Hossein Arabi, Andrew L Goertzen

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. The electronic structure of KJournal of materials chemistry. C · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Amir BeheshtiFaculty of Physics, University of Isfahan, Isfahan, Iran. beheshti.amir86@gmail.com.
Alireza KarimianDepartment of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran. karimian@eng.ui.ac.ir.
Hossein ArabiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, 1211, Geneva, Switzerland.
Andrew L GoertzenDepartment of Radiology, University of Manitoba, Winnipeg, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In PET systems, the SNR relies on the coincidence time resolution (CTR) of 511 keV photon pairs. This research investigates the impact of reflectors, surface treatments, materials, and scintillation crystal length on the CTR of a brainPET detector using dual-layer offset scintillators (DLOs). This study is based on a brainPET, under development at the University of Manitoba, to propose a new design to achieve an improved CTR. Four different pairs of LYSO crystals with distinct optical compositions, surface treatments, and reflective materials were simulated (using GATEv9.3). Each model comprises two LYSO crystal with dimensions of 3 × 3  × 10 mm

Indexed as

Coincidence time resolutionDual-layer offset detectorEnergy resolutionPositron emission tomographyReflectorsTime of flight

Identifiers

PMID40325096
PMCPMC12053691

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.