Evidence map›Paper›PMID 40324167›Full record

ArticleJournal of medical Internet research2025

Current Technological Advances in Dysphagia Screening: Systematic Scoping Review.

Duo Wai-Chi Wong, Jiao Wang, Sophia Ming-Yan Cheung, Derek Ka-Hei Lai, Armstrong Tat-San Chiu, Dai Pu, James Chung-Wai Cheung, Timothy Chi-Yui Kwok

Abstract readScoping Review
In one paragraph

Article in Journal of medical Internet research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Duo Wai-Chi WongDepartment of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Hong Kong, China (Hong Kong).ORCID https://orcid.org/0000-0002-8805-1157
Jiao WangDepartment of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Hong Kong, China (Hong Kong).ORCID https://orcid.org/0009-0008-1025-6452
Sophia Ming-Yan CheungDepartment of Mathematics, School of Science, Hong Kong University of Science and Technology, Hong Kong, China (Hong Kong).ORCID https://orcid.org/0009-0006-4340-2343
Derek Ka-Hei LaiDepartment of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Hong Kong, China (Hong Kong).ORCID https://orcid.org/0000-0003-3950-871X
Armstrong Tat-San ChiuKowloon Home for the Aged Blind, Hong Kong Society for the Blind, Hong Kong, China (Hong Kong).ORCID https://orcid.org/0000-0002-3805-2880
Dai PuSchool of Primary and Allied Health Care, Monash University, Melbourne, Australia.ORCID https://orcid.org/0000-0002-6268-4378
James Chung-Wai CheungDepartment of Biomedical Engineering, Faculty of Engineering, Hong Kong Polytechnic University, Hong Kong, China (Hong Kong).ORCID https://orcid.org/0000-0001-7446-0569
Timothy Chi-Yui KwokDepartment of Medicine and Therapeutics, Faculty of Medicine, Chinese University of Hong Kong, Hong Kong, China (Hong Kong).ORCID https://orcid.org/0000-0001-9253-3549

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDysphagia affects more than half of older adults with dementia and is associated with a 10-fold increase in mortality. The development of accessible, objective, and reliable screening tools is crucial for early detection and management.

objectiveThis systematic scoping review aimed to (1) examine the current state of the art in artificial intelligence (AI) and sensor-based technologies for dysphagia screening, (2) evaluate the performance of these AI-based screening tools, and (3) assess the methodological quality and rigor of studies on AI-based dysphagia screening tools.

methodsWe conducted a systematic literature search across CINAHL, Embase, PubMed, and Web of Science from inception to July 4, 2024, following the PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews) framework. In total, 2 independent researchers conducted the search, screening, and data extraction. Eligibility criteria included original studies using sensor-based instruments with AI to identify individuals with dysphagia or unsafe swallow events. We excluded studies on pediatric, infant, or postextubation dysphagia, as well as those using non-sensor-based assessments or diagnostic tools. We used a modified Quality Assessment of Diagnostic Accuracy Studies-2 tool to assess methodological quality, adding a "model" domain for AI-specific evaluation. Data were synthesized narratively.

resultsThis review included 24 studies involving 2979 participants (1717 with dysphagia and 1262 controls). In total, 75% (18/24) of the studies focused solely on per-individual classification rather than per-swallow event classification. Acoustic (13/24, 54%) and vibratory (9/24, 38%) signals were the primary modality sources. In total, 25% (6/24) of the studies used multimodal approaches, whereas 75% (18/24) used a single modality. Support vector machine was the most common AI model (15/24, 62%), with deep learning approaches emerging in recent years (3/24, 12%). Performance varied widely-accuracy ranged from 71.2% to 99%, area under the receiver operating characteristic curve ranged from 0.77 to 0.977, and sensitivity ranged from 63.6% to 100%. Multimodal systems generally outperformed unimodal systems. The methodological quality assessment revealed a risk of bias, particularly in patient selection (unclear in 18/24, 75% of the studies), index test (unclear in 23/24, 96% of the studies), and modeling (high risk in 13/24, 54% of the studies). Notably, no studies conducted external validation or domain adaptation testing, raising concerns about real-world applicability.

conclusionsThis review provides a comprehensive overview of technological advancements in AI and sensor-based dysphagia screening. While these developments show promise for continuous long-term tele-swallowing assessments, significant methodological limitations were identified. Future studies can explore how each modality can target specific anatomical regions and manifestations of dysphagia. This detailed understanding of how different modalities address various aspects of dysphagia can significantly benefit multimodal systems, enabling them to better handle the multifaceted nature of dysphagia conditions.

Indexed as

Artificial IntelligenceDeglutition DisordersMass ScreeningHumansAIartificial intelligenceaspirationcomputational deglutitioncomputer-aided diagnosisdeep learningdigital healthmachine learningswallowing disorder

Identifiers

PMID40324167
PMCPMC12089864

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.