ArticleThe Journal of small animal practice2025
Stabilisation of thoracolumbar vertebral fractures and luxations in cats with a polyaxial screw/rod system.
Article in The Journal of small animal practice, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- The Effects of Diagnostic Anatomical Features on Treatment and Recovery in Feline Spinal Trauma.Veterinary sciences · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThe purpose of this study was to determine clinical and neurological data on the stabilisation of thoracolumbar region fractures or luxations in cats with the polyaxial screw rod system. MATERIALS AND
methodsThe study included 16 cats with thoracic and/or lumbar fractures, luxations and/or instability. Data recorded for each patient included history, cause of vertebral fractures and dislocations, concurrent injury, time to surgery, neurologic examination and neurologic grading preoperatively and postoperatively (postoperatively, week 1, week 3 and month 6), surgical treatment, preoperative x-ray and postoperative computed tomography imaging findings.
resultsThe region with the most localized lesions was T3-L3 in ten cases and L4-L7 in six cases. Polyaxial screws were placed unilaterally in 13 cases and bilaterally in three cases. A total of 50 polyaxial screws were placed in all cases. Of these, 44 polyaxial screws were placed optimally, four polyaxial screws were breached (screw diameter breach <2 mm) and two screws were broken. Broken screws did not require any revisions. Although 11 of the cases showed improvement in terms of neurological grading, no improvement was observed in five cases. The clinical outcome was excellent in four cases, functional in six cases and poor in six cases. CLINICAL SIGNIFICANCE: The polyaxial screw rod system described here is a potential option for stabilization of thoracolumbar vertebrae in cats.