Evidence map›Paper›PMID 40318257›Full record

ArticleClinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology2025

Deep learning-based EEG source imaging is robust under varying electrode configurations.

Jesse Rong, Rui Sun, Boney Joseph, Greg Worrell, Bin He

Abstract read
In one paragraph

Article in Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jesse RongDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, United States.
Rui SunDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, United States.
Boney JosephDepartment of Neurology, Mayo Clinic, Rochester, MN, United States.
Greg WorrellDepartment of Neurology, Mayo Clinic, Rochester, MN, United States.
Bin HeDepartment of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, United States. Electronic address: bhe1@andrew.cmu.edu.

Funding

Electrophysiological Source Imaging of Partial EpilepsyR01NS096761 · NINDS · UNIVERSITY OF MINNESOTA · PI HE, BIN · 2016 to 2025
$3.6M
Electrophysiology-Compatible Wearable Transcranial Focused Ultrasound Neuromodulation Array ProbesRF1NS131069 · NINDS · CARNEGIE-MELLON UNIVERSITY · PI HE, BIN · 2023 to 2023
$3.6M
Imaging Epilepsy Sources with Biophysically Constrained Deep Neural NetworksR01NS127849 · NINDS · CARNEGIE-MELLON UNIVERSITY · PI BIN HE · 2023 to 2026
$2.4M
Characterization of in vivo neuronal and inter-neuronal responses to transcranial focused ultrasoundR01NS124564 · NINDS · CARNEGIE-MELLON UNIVERSITY · PI HE, BIN · 2021 to 2021
$2.0M
Integrative Training in Neural InterfacingT32EB029365 · NIBIB · CARNEGIE-MELLON UNIVERSITY · PI HE, BIN · 2021 to 2025
$1.0M
Characterization of in vivo neuronal and inter-neuronal responses to transcranial focused ultrasoundRF1NS124564 · NINDS · CARNEGIE-MELLON UNIVERSITY · PI HE, BIN · 2025 to 2025
$571k
NIBIB NIH HHS T32 EB029365NINDS NIH HHS R01 NS096761NINDS NIH HHS R01 NS124564NINDS NIH HHS R01 NS127849NINDS NIH HHS RF1 NS124564NINDS NIH HHS RF1 NS131069
6 · The paper itself

Abstract

objectivesPrevious research has underscored the necessity of high-density EEG for accurate and reliable EEG source imaging (ESI) results with conventional ESI methods, limiting their utility in clinical settings with only low-density EEG available. In recent years, deep learning-based ESI methods have exhibited robust performance by directly learning spatiotemporal brain activity patterns from data.

methodsThis study investigates the impact of EEG electrode number on a newly proposed Deep Learning-based Source Imaging Framework (DeepSIF). Through computer simulations and clinical data analysis, we assess ESI performance across various channel configurations (16, 21, 32, 64, and 75 channels) comparing DeepSIF and conventional methods against the simulated ground truth and clinical reference regions.

resultsOur results indicate that DeepSIF consistently delivers accurate source localization and extent estimations across different channel counts and noise levels, surpassing conventional methods. In a cohort of 27 drug-resistant epilepsy patients, the average spatial dispersions for DeepSIF, sLORETA and LCMV are 7.9/9.0 mm, 21.9/28.1 mm, and 20.0/28.9 mm, respectively when using 75/16 electrodes.

conclusionsOur results indicate the robust performance of DeepSIF algorithm for source imaging with low-density EEG. SIGNIFICANCE: Our findings suggest broad applications of the deep-learning based source imaging in clinical settings without the need for high-density EEG devices.

Indexed as

Deep LearningElectroencephalographySignal Processing, Computer-AssistedBrainElectrodesHumansModels, NeurologicalSoftware ValidationDeep Neural NetworksElectrode Number, EEGElectrophysiological Source ImagingSource Localization

Identifiers

PMID40318257
PMCPMC12629399

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.