A novel wearable sensor for objective measurement of distance and illumination.

Raman Prasad Sah, Pavan Kalyan Narra, Lisa A Ostrin

Abstract read
In one paragraph

Article in Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Guideline
  2. Myopia Prevalence, Ocular Metrics and Visual Activity in United States Optometry Students.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
    Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Raman Prasad SahUniversity of Houston College of Optometry, Houston, Texas, USA.ORCID https://orcid.org/0000-0003-4591-5012
Pavan Kalyan NarraUniversity of Houston College of Optometry, Houston, Texas, USA.
Lisa A OstrinUniversity of Houston College of Optometry, Houston, Texas, USA.ORCID https://orcid.org/0000-0001-8675-1478

Funding

Light, near work, and ocular remodeling and during emmetropization and myopia development in childrenR01EY030193 · NEI · UNIVERSITY OF HOUSTON · PI Lisa A Ostrin, Jason Porter · 2019 to 2026
$2.7M
NEI NIH HHS R01 EY030193
6 · The paper itself

Abstract

purposeTo evaluate the rangefinding and light sensing capabilities of a novel wearable sensor, the Visual Environment Evaluation Tool (VEET) developed for myopia research.

methodsThe VEET 1.0 (Meta, LLC) is a temple-integrated system mounted on a spectacle frame. Both the left and right temples house four sensors each, angled straight ahead and 20° downward/4° nasal, respectively. For validation, VEET-mounted spectacles were placed on a mannequin head. An infrared camera was used to capture the spatial characteristics of the rangefinding beam. Distance measurements were collected against a wall for 5-400 cm. The accuracy of distance measurements for different target types, sizes and tilt was assessed. Ambient illumination was captured in different indoor and outdoor settings and compared to a lux meter.

resultsAll devices (N = 20) were capable of capturing distances for the full range evaluated, 5-400 cm, against a wall. There was a strong relationship between the actual and measured distances, with a slope of 1.01 ± 0.003 and 0.95 ± 0.007, for the left and right temples, respectively. Distance measurements were repeatable across different target types, including paper and tablet. Mean beam diameter of five tested devices was 52.2° ± 7.5°. The VEET effectively measured distances across different target sizes, ranging from 2 × 2 cm and larger and target tilt ±60°. Illumination measurements across different indoor and outdoor settings demonstrated a strong linear relationship with lux meter readings (R

conclusionThe VEET provides accurate quantification of real-time distances across different target types and sizes and is capable of effectively distinguishing indoor and outdoor illumination levels. The VEET will be valuable in studies evaluating risk factors for myopia to gain a better understanding of the role of near work and light exposure.

Indexed as

EyeglassesLightingMyopiaWearable Electronic DevicesEquipment DesignHumansambient illuminationmyopianear workrisk factorswearable sensors

Identifiers

PMID40318162
PMCPMC12916105

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.