Evidence map›Paper›PMID 40317734›Full record

ArticleMedical physics2025

Instantaneous in vivo distal edge verification in intensity-modulated proton therapy by means of PET imaging.

Brian Zapien-Campos, Zahra Ahmadi Ganjeh, Giuliano Perotti-Bernardini, Jeffrey Free, Stefan Both, Peter Dendooven

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Brian Zapien-CamposParticle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Zahra Ahmadi GanjehDepartment of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Giuliano Perotti-BernardiniDepartment of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Jeffrey FreeDepartment of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Stefan BothDepartment of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Peter DendoovenParticle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.

Funding

Dutch Cancer Society 13420Dutch Cancer Society 1342240Siemens Healthineers
6 · The paper itself

Abstract

backgroundIntensity-modulated proton therapy (IMPT) holds promise for improving outcomes in head-and-neck cancer (HNC) patients by enhancing organ-at-risk (OAR) sparing. A key challenge in IMPT is ensuring an accurate dose delivery at the distal edge of the tumor, where the steep dose gradients make treatment precision highly sensitive to uncertainties in both proton range and patient setup. Thus, IMPT conformality is increased by incorporating robust margins in the treatment optimization. However, an increment in the plan robustness could lead to an OAR overdosing. Therefore, an accurate distal edge verification during dose delivery is crucial to increase IMPT conformality by reducing optimization settings in treatment planning. PURPOSE: This work aims to evaluate, in a quasi-clinical setting, a novel approach for accurate instantaneous proton beam distal edge verification in IMPT by means of spot-by-spot positron emission tomography (PET) imaging.

methodsAn anthropomorphic head and neck phantom CIRS-731 HN was irradiated at the head and neck region. The targets were defined as 4 cm diameter spheres. A 60-ms delay was introduced between the proton beam spots in order to enable the spot-by-spot coincidence detection of the 511-keV photons resulting from positron annihilation following the positron emission from very short-lived positron-emitting, mainly

resultsPAR measurements achieved a precision between 1.5 and 3.6 mm (at 1.5σ clinical level) at the beam spot level within sub-second time scales. Measured PAR shifts of 1.6-2.1  and 4.2--.7 mm were observed with the 2- and 5-mm thickness range shifters, respectively, aligning with the corresponding proton dose range (PDR) shifts of 1.3-1.8 and 3.9-4.3 mm. The simulated PAR agrees with the measured PARs, showing an average range difference of ∼0.4 mm.

conclusionThis study demonstrated the feasibility of instantaneous distal edge verification using PET imaging by introducing beam spot delays during dose delivery. The findings represent a first step toward the clinical implementation of instantaneous in vivo distal edge verification. The approach contributes to the development of real-time range verification aimed at improving IMPT treatments by mitigating range and setup uncertainties, thereby reducing dose to organs-at-risk and ultimately enhancing patient outcomes.

Indexed as

Positron-Emission TomographyProton TherapyRadiotherapy, Intensity-ModulatedHead and Neck NeoplasmsHumansPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-Assistedintensity‐modulated proton therapyMonte Carlo simulationpositron emission tomographyrange verification

Identifiers

PMID40317734
PMCPMC12257898

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.