Evidence map›Paper›PMID 40316507›Full record

ArticleThe British journal of radiology2025

Impact of new X-ray technology reducing patient and staff doses in interventional cardiology.

Roberto Mariano Sánchez-Casanueva, Eliseo Vano-Carruana, José Miguel Fernández-Soto

Abstract read
In one paragraph

Article in The British journal of radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Roberto Mariano Sánchez-CasanuevaInstituto de Investigación Sanitaria del Hospital Clínico San Carlos and Medical Physics Service, Madrid 28040, Spain.ORCID 0000-0003-3130-2362
Eliseo Vano-CarruanaInstituto de Investigación Sanitaria del Hospital Clínico San Carlos and Medical Physics Service, Madrid 28040, Spain.
José Miguel Fernández-SotoInstituto de Investigación Sanitaria del Hospital Clínico San Carlos and Medical Physics Service, Madrid 28040, Spain.ORCID 0000-0002-5297-4611

Funding

Consejo de Seguridad NuclearSpanish Regulatory Body
6 · The paper itself

Abstract

objectivesThe radiology industry has been developing advanced X-ray systems which now deliver high-quality imaging while reducing radiation exposure. In this study, we analyse the impact of the new X-ray systems on patient and occupational radiation doses, compared with the previous ones (from the same manufacturer).

methodsA dose management system (DMS) was employed to analyse large datasets from interventional cardiology procedures to assess the radiation protection improvements. Interventionists wear electronic active dosimeters wirelessly linked to the DMS to record personal occupational doses. Our analysis was conducted at 4 levels for the old and new X-ray systems: patient doses, using the kerma area product (KAP); scatter radiation measured by the reference (ambient) dosimeter located on the C-arm; occupational doses using over-apron personal electronic dosimeters, and updating local diagnostic reference levels (DRLs) for the most frequent procedures.

resultsThis methodology enables the evaluation of the new technology's impact at different levels: patient dose values (level 1), scatter radiation measured by the ambient dosimeters (level 2), occupational doses for interventionists (level 3), and updated local DRLs (level 4).

conclusionsBased on an analysis of 5002 interventional cardiology procedures, the new X-ray systems demonstrated a substantial reduction in radiation doses (median values): patient doses (KAP values) decreased by 56%-67%. Scatter radiation (ambient dose) decreased by 52%-68%. Occupational doses: interventionists' doses decreased by 33%. The updated local DRLs (median values) for CA and PTCA with the new X-ray systems are 17 Gy·cm2 and 50 Gy·cm2 representing reductions of 62% and 52%, respectively. ADVANCES IN KNOWLEDGE: The implementation of advanced X-ray technology has significantly reduced patient and occupational radiation exposure, all without compromising diagnostic accuracy. The effects on local diagnostic reference levels and the reduction in occupational doses should be regularly assessed to ensure that appropriate optimization actions are maintained.

Indexed as

CardiologyOccupational ExposureRadiation DosageRadiation ExposureRadiation ProtectionRadiography, InterventionalHumansX-Raysdiagnostic reference levelsinterventional cardiologynew technologyoccupational dosepatient dose

Identifiers

PMID40316507
PMCPMC12201983

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.