Evidence map›Paper›PMID 40315867›Full record

ArticleAorta (Stamford, Conn.)2024

High Flow, High-Pressure Retrograde Cerebral Perfusion at 28°C is Safe and Effective for Hemiarch Replacement of the Ascending Aorta.

R Wilson King, Adam M Carroll, Michal Schäfer, Zihan Feng, Jintong W Liu, George A Justison, Joseph C Cleveland, Jessica Y Rove, Muhammad Aftab, T Brett Reece

Abstract read
In one paragraph

Article in Aorta (Stamford, Conn.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Origin of prefabricated frozen elephant trunk.Annals of cardiothoracic surgery · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

R Wilson KingDepartment of Surgery, University of Colorado, Denver, Colorado.ORCID 0000-0002-0336-6038
Adam M CarrollDepartment of Surgery, University of Colorado, Denver, Colorado.
Michal SchäferDepartment of Surgery, University of Colorado, Denver, Colorado.
Zihan FengDepartment of Surgery, University of Colorado, Denver, Colorado.
Jintong W LiuDepartment of Surgery, University of Colorado, Denver, Colorado.
George A JustisonDepartment of Cardiothoracic Surgery, University of Colorado, Denver, Colorado.
Joseph C ClevelandDepartment of Cardiothoracic Surgery, University of Colorado, Denver, Colorado.
Jessica Y RoveDepartment of Cardiothoracic Surgery, University of Colorado, Denver, Colorado.
Muhammad AftabDepartment of Cardiothoracic Surgery, University of Colorado, Denver, Colorado.
T Brett ReeceDepartment of Cardiothoracic Surgery, University of Colorado, Denver, Colorado.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Traditional retrograde cerebral perfusion (RCP) parameters may be suboptimal for washout of debris during hemiarch replacement of the ascending aorta, so we have designed a protocol of increased RCP pressure and flow at moderate hypothermia. We hypothesize that higher RCP pressure is safe in neurological outcomes in cases utilizing circulatory arrest at 28°C in elective hemiarch replacement.A retrospective review of a single-institution prospective database was used to search for all patients with elective hemiarch surgery from 2015 to 2022. Two cohorts were created-patients who received RCP only during circulatory arrest at 28°C and patients who received selective antegrade cerebral perfusion (SACP) during circulatory arrest. Neurological and postoperative outcomes were compared. Arterial blood gas measurements during RCP were taken from the left carotid of 34 patients, which were compared with the arterial blood gas from the bypass circuit to ensure adequate oxygen extraction. Propensity score matching was used to adjust for perioperative indices and patient characteristics.A total of 248 patients were in the SACP cohort and 79 patients in the RCP cohort. The two groups were similar based on patient demographics and relevant comorbidities. The cohorts differed in nadir bladder temperature, circulatory arrest time, and cardiopulmonary bypass time. After propensity matching, nadir bladder temperature, circulatory arrest, and cardiopulmonary bypass times were similar. Neurological postoperative outcomes were similar in the unmatched and matched analysis. The median pressure in the RCP group during circulatory arrest was 40 mm Hg. The median change in oxygen from bypass circuit to the carotids is 398 mm Hg with a mean oxygen extraction of 93.3%.These data demonstrate that a more aggressive approach to RCP beyond traditional constraints at 28°C is safe for short periods of circulatory arrest. Even with the new RCP parameters and after adjusting for standard patient and perioperative characteristics, there is no difference between SACP and RCP in neurological outcomes. Further, adequate oxygen extraction is achieved during RCP.

Identifiers

PMID40315867
PMCPMC12185165

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.