Impact of Prosthetic Angle Variations in Combined Anteversion Technique on Surgical Failure Rates in Developmental Dysplasia of the Hip: A 12-Year Follow-Up Study.

Hua Qiao, Keyu Kong, Yongyun Chang, Minghao Jin, Xiaokun Chen, Zanjing Zhai, Yuanqing Mao, Zhenan Zhu, Yu Shan, Huiwu Li and 1 more

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Hua QiaoShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopaedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China.
Keyu KongShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopaedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China.
Yongyun ChangShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopaedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China.
Minghao JinShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopaedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China.
Xiaokun ChenShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopaedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China.
Zanjing ZhaiShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopaedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China.ORCID https://orcid.org/0000-0002-0312-7539
Yuanqing MaoShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopaedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China.
Zhenan ZhuShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopaedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China.
Yu ShanSuzhou Ninth People's Hospital, Department of Orthopedics, Suzhou Ninth Hospital Affiliated to Soochow University, Suzhou, People's Republic of China.
Huiwu LiShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopaedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China.ORCID https://orcid.org/0000-0002-2084-2737
Jingwei ZhangShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopaedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, People's Republic of China.ORCID https://orcid.org/0000-0003-0714-4966

Funding

Fundamental Research Funds for the Central Universities YG2023ZD15National Natural Science Foundation of China 31900941Shanghai "Rising Stars of Medical Talent" Youth Development Program SHHWRS 2023-62
6 · The paper itself

Abstract

objectivesThe combined anteversion technique was introduced to guide prosthesis orientation in patients with developmental dysplasia of the hip and has achieved favorable short-term results in a previously published series. However, excessive variations in implant orientation may increase the risk of accelerated polyethylene wear and lead to revision THA. This study aimed to report whether the variation in implant orientation caused by the combined anteversion technique would result in an increased surgical failure rate and the mid- to long-term clinical outcome in total hip arthroplasty for patients with hip dysplasia. MATERIALS AND

methodsThis retrospective study reviewed patients with hip dysplasia who underwent total hip arthroplasty with the combined anteversion technique between 2007 and 2012 at our center. The surgical protocol prioritized the combined anteversion principle, requiring maintenance of the combined anteversion within the 25°-50° range while permitting physiological variation in individual femoral or acetabular component positioning. In total, 55 patients (80 hips) were included, with an average follow-up period of 12.7 years (range, 11 to 16). Ceramic fragmentation, periprosthetic radiolucencies, and osteolysis around the cup and stem were evaluated based on the immediate postoperative pelvic anteroposterior radiographs and the last follow-up. Femoral, acetabular, and combined anteversions pre-and postoperatively were measured using CT-based models. The Harris hip score at the latest follow-up was used for comparison with the score before surgery.

resultsThe average Harris hip score increased from 28.3 ± 10.1 preoperatively to 91.2 ± 6.7 (p < 0.01) at the last follow-up. The mean femoral, acetabular, and combined anteversions were 25.6° ± 11.1° and 23.7° ± 10.6°, 23.2° ± 7.4° and 19.8° ± 8.3°, and 48.7° ± 12.9° and 43.1° ± 6.8° preoperatively and postoperatively, respectively. By the last follow-up, one patient developed periprosthetic osteolysis 11 years after primary surgery without obvious periprosthetic loosening and migration of the femoral head rotation center. Two patients experienced prosthesis dislocation, one of whom received a revision 4 years after primary surgery, and the other underwent manual reduction under anesthesia 8 years after primary surgery. Two patients underwent revision and internal fixation due to prosthesis loosening caused by a periprosthetic fracture 10 years and 12 years after primary surgery.

conclusionThe combined anteversion technique in total hip arthroplasty for patients with hip dysplasia yielded reliable mid-to-long-term results. This technique's changes in prosthesis angle did not significantly increase the surgical failure rate.

Indexed as

Arthroplasty, Replacement, HipDevelopmental Dysplasia of the HipHip ProsthesisProsthesis FailureAdultAgedFemaleFollow-Up StudiesHumansMaleMiddle AgedProsthesis DesignReoperationRetrospective Studiescombined anteversiondevelopmental dysplasia of the hipsurgical techniquetotal hip arthroplasty

Identifiers

PMID40312998
PMCPMC12146111

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.