ArticleNeuroradiology2025
Early detection of contrast-induced encephalopathy after mechanical thrombectomy using flat-detector CT: incidence, risk factors, and clinical implications.
Article in Neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeContrast-induced encephalopathy (CIE) is a rare but increasingly recognized complication following therapeutic and diagnostic endovascular neurointerventions, including mechanical thrombectomy (MT). This study aimed to investigate the incidence, imaging characteristics, and risk factors of CIE, utilizing flat-detector (FD) CT for immediate post-interventional assessment.
methodsWe retrospectively evaluated patients who underwent MT for acute ischemic stroke (AIS) between January 2020 and February 2023, who received FDCT directly after the intervention. CIE was diagnosed based on clinical criteria and radiological findings, confirmed with follow-up dual-energy (DE)-CT. Risk factors for CIE were analyzed using logistic regression, and associations with clinical outcomes (discharge mRS and mortality) were assessed.
resultsCIE was identified in 16 patients of 339 (4.7%). Patients who developed CIE required a significantly higher number of device passes (median: 3 vs. 2, p = 0.033) and contrast volume exposure (200 mL vs. 110 mL, p = 0.017). Cervical ICA occlusion (p = 0.025) and intracranial stent angioplasty (p = 0.047) were frequent in the CIE group. Logistic regression confirmed the number of device passes as an independent predictor of CIE (OR: 1.51; 95% CI: 1.13-2.01; p = 0.005). No significant associations were found between CIE and unfavorable clinical outcomes (mRS > 3, p = 0.9) or mortality (p = 0.89).
conclusionFDCT allows for early detection of CIE-related radiological changes immediately after MT. Procedural complexity, including device passes, was identified as a risk factor. Identifying other risk factors require further investigations, due to the low incidence rate of detected CIE. These findings highlight the need for intensified monitoring for high-risk patients to mitigate the risk of CIE.