Evidence map›Paper›PMID 40308877›Full record

ArticleAsia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology2025

Influence of limb position on femoral neck anteversion angle measurement during computed tomography imaging.

Rika Shigemoto, Takehiko Matsushita, Kyohei Nishida, Kanto Nagai, Yuta Nakanishi, Tetsuya Yamamoto, Tomoyuki Matsumoto, Noriyuki Kanzaki, Yuichi Hoshino, Ryosuke Kuroda

Abstract read
In one paragraph

Article in Asia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Rika ShigemotoDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Japan.
Takehiko MatsushitaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Japan.
Kyohei NishidaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Japan.
Kanto NagaiDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Japan.
Yuta NakanishiDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Japan.
Tetsuya YamamotoDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Japan.
Tomoyuki MatsumotoDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Japan.
Noriyuki KanzakiDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Japan.
Yuichi HoshinoDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Japan.
Ryosuke KurodaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The femoral neck anteversion angle has been used as a surgical indicator for hip and patellofemoral joint disorders. However, the influence of limb position on femoral neck anteversion angle measurements during imaging remains unclear. Therefore, this study aimed to investigate the influence of limb position on femoral neck anteversion angle measurements. Methods: Computed tomography images of 20 femurs from 10 patients were obtained. The angle between the line passing through the center of the femoral head and the center of the femoral neck and the tangential line of the femoral posterior condyles on axial slices was measured as the femoral neck anteversion angle. Raw femoral neck anteversion angle data was defined as the original femoral neck anteversion angle. The cutting direction of the axial plane was changed from -20° to 20° in 5° increments to simulate limb position changes for each of the following measurements: hip flexion/extension, abduction/adduction angles, and their combined directions. The femoral neck anteversion angle was measured under each condition, and the change in the angle was calculated. The correlation between hip angle and femoral neck anteversion angle change was analysed by Spearman's rank correlation coefficient. Results: The mean original femoral neck anteversion angle was 17.6°. There was a strong negative correlation between hip flexion/extension change and femoral neck anteversion angle change ( Conclusions: The femoral neck anteversion angle changed in association with changes in limb position, particularly with hip flexion and extension. Careful attention to limb position and conditions of the slice is needed to consistently evaluate the femoral neck anteversion angle.

Indexed as

Computed tomographyFemoral anteversionFemoral neck anteversion angle

Identifiers

PMID40308877
PMCPMC12043011

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.